EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitMetaanalyseOpen Access · CC BY 4.0

Pulsed Field Ablation Versus High-Power Short-Duration Ablation for Atrial Fibrillation—A Meta-Analysis of Reconstructed Time-to-Event Data

Pedro B Bregion, Felipe S Passos iD, Stefano Schena iD, Luca Fazzini iD, Hristo Kirov iD, Camilla S Rossi iD, Torsten Doenst iD, Antonino Di Franco, Tulio Caldonazo iD

Journal of Cardiovascular Development and Disease · 26.04.2026 · 13 (5) · 181

DOI: 10.3390/jcdd13050181 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Journal of Cardiovascular Development and Disease, online erschienen am 26.04.2026. Verfasst von Pedro B Bregion und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, State University of Campinas, Campinas 13083-970, Brazil. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, Deutsche Herzstiftung, Interdisciplinary Center of Clinical Research of the Medical Faculty Jena.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pulsed field ablation (PFA) has shown promising results for atrial fibrillation (AF), with efficacy comparable to established ablation techniques. High-power short-duration (HPSD) ablation has also emerged as a potential alternative. However, the relative superiority between these approaches remains uncertain. We performed a systematic review and meta-analysis to address this gap.

Methods

Three databases were searched. The primary outcome was freedom from AF recurrence. Secondary outcomes included tamponade and other complications, procedure and fluoroscopy durations. Time-to-event data were reconstructed, and a random-effects model was employed. Given variability in post-ablation blanking periods across studies, landmark analyses were performed using a 3-month cut-off to account for the potential under-detection of early recurrence events.

Results

Eight studies (1369 patients [PFA: 642; HPSD: 727]) were included. PFA was associated with greater freedom from AF recurrence (HR 0.751; 95% CI 0.57 to 0.99; p = 0.044). Landmark analyses showed no difference in the 0–3 month period; a significant benefit of PFA was observed thereafter (HR 0.72; 95% CI 0.54 to 0.98; p = 0.033). There were no significant differences between groups in the incidence of tamponade (p = 0.73) or overall complications (p = 0.99). PFA was associated with shorter procedure duration (MD 37.05; 95% CI 27.69 to 46.41; p < 0.01), whereas fluoroscopy duration was significantly shorter in the HPSD group (MD −9.04; 95% CI −11.71 to −6.37; p < 0.001).

Conclusion

PFA was associated with a lower risk of AF recurrence compared to HPSD, particularly beyond the late post-ablation period, with similar rates of complications. Although PFA was associated with shorter procedure duration, HPSD demonstrated reduced fluoroscopy time.

Schlagwörter

Stichwörter der Autor:innen

atrial fibrillationhigh-power short durationpulsed field ablation

Autor:innen und Institutionen

  • Department of Medicine, State University of Campinas, Campinas 13083-970, Brazil.
  • Department of Thoracic Surgery, MaterDei Hospital, Salvador 40220-005, Brazil.
  • Division of Cardiac Surgery, Medical College of Wisconsin, Milwaukee, WI 53226, USA.
  • Clinical Cardiology Unit, Department of Medical Sciences and Public Health, University of Cagliari, 09042 Cagliari, Italy.
  • Department of Cardiothoracic Surgery, Friedrich-Schiller-University Jena, 07747 Jena, Germany.
  • Department of Cardiothoracic Surgery, Weill Cornell Medicine, New York, NY 10065, USA.

ORCID-Profile: Felipe S Passos, Stefano Schena, Luca Fazzini, Hristo Kirov, Camilla S Rossi, Torsten Doenst, Tulio Caldonazo

Förderung

  • Deutsche Forschungsgemeinschaft
  • Deutsche Herzstiftung
  • Interdisciplinary Center of Clinical Research of the Medical Faculty Jena

Zitieren

APA

Bregion, P. B., Passos, F. S., Schena, S., Fazzini, L., Kirov, H., Rossi, C. S., Doenst, T., Di Franco, A., & Caldonazo, T. (2026). Pulsed Field Ablation Versus High-Power Short-Duration Ablation for Atrial Fibrillation—A Meta-Analysis of Reconstructed Time-to-Event Data. Journal of Cardiovascular Development and Disease, 13(5), 181. https://doi.org/10.3390/jcdd13050181

Vancouver

Bregion PB, Passos FS, Schena S, Fazzini L, Kirov H, Rossi CS, et al. Pulsed Field Ablation Versus High-Power Short-Duration Ablation for Atrial Fibrillation—A Meta-Analysis of Reconstructed Time-to-Event Data. Journal of Cardiovascular Development and Disease. 2026;13(5):181. doi:10.3390/jcdd13050181

BibTeX
@article{Bregion2026,
  author = {Bregion, Pedro B and Passos, Felipe S and Schena, Stefano and Fazzini, Luca and Kirov, Hristo and Rossi, Camilla S and Doenst, Torsten and Di Franco, Antonino and Caldonazo, Tulio},
  title = {Pulsed Field Ablation Versus High-Power Short-Duration Ablation for Atrial Fibrillation—A Meta-Analysis of Reconstructed Time-to-Event Data},
  journal = {Journal of Cardiovascular Development and Disease},
  year = {2026},
  volume = {13},
  number = {5},
  pages = {181},
  doi = {10.3390/jcdd13050181}
}
Kostenlos starten →