EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitSystematische ÜbersichtOpen Access · CC BY 4.0

Systematic Review on HRV Reference Values

Maximillian Brozat, Irina Böckelmann iD, Stefan Sammito iD

Journal of Cardiovascular Development and Disease · 06.06.2025 · 12 (6) · 214

DOI: 10.3390/jcdd12060214 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Journal of Cardiovascular Development and Disease, online erschienen am 06.06.2025. Verfasst von Maximillian Brozat und 2 weiteren Autor:innen. Beteiligte Einrichtung: German Air Force Centre of Aerospace Medicine, 51147 Cologne, Germany. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 78 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Heart rate variability (HRV) has been established as a measure for the variation in time intervals between successive cardiac actions as a marker of the autonomic nervous system. However, despite many efforts in this field, there are no reference values that are generally accepted. The objective of this systematic review is, therefore, to present an overview of the studies on HRV normal values published to date, with due consideration of any influencing factors. A systematic database query was carried out in PubMed, Scopus, Ovid Medline, and PsychInfo using the search string “((hrv) or (heart rate variability)) and ((reference values) or (reference range) or (normal values))”. Of the 6640 studies yielded by the query, 58 were used for this systematic review. The STARD-HRV procedure was used to assess the quality of the studies. The studies considered date from 1989 to 2022. The number of subjects examined was between 20 and 84,772. The age of the subjects was between 1 day and 99 years. A total of 51 of the studies examined both male and female subjects. In total, 19 studies used long-term measurements, 22 studies used short-term measurements, and 17 studies used intermediate measuring periods. Many different HRV parameters were analyzed, most often traditional time-domain and frequency-domain ones. Nine studies described the subjects as “healthy” without giving more detailed explanations. There are no generally accepted HRV normal values (yet). Some large studies provide values that may be used for orientation purposes. However, further studies are required to collect HRV normal values. It was not possible to merge the results of the studies in terms of a meta-analysis; this would also not be practical since, among other reasons, the consideration of confounders as well as recording and measuring modalities sometimes vary to a large extent and impede the comparability of the studies. Generally, HRV seems to be influenced by various mechanisms and external factors that are still not fully understood. An exploration of these factors will ultimately allow HRV normal values to be obtained in a manner that is generally accepted.

Schlagwörter

Stichwörter der Autor:innen

autonomous nervous systemheart diseasesnorm valuesparasympatheticsympathetic

Autor:innen und Institutionen

  • German Air Force Centre of Aerospace Medicine, 51147 Cologne, Germany.
  • Department of Occupational Medicine, Faculty of Medicine, Otto von Guericke University of Magdeburg, 39120 Magdeburg, Germany.

ORCID-Profile: Irina Böckelmann, Stefan Sammito

Zitieren

APA

Brozat, M., Böckelmann, I., & Sammito, S. (2025). Systematic Review on HRV Reference Values. Journal of Cardiovascular Development and Disease, 12(6), 214. https://doi.org/10.3390/jcdd12060214

Vancouver

Brozat M, Böckelmann I, Sammito S. Systematic Review on HRV Reference Values. Journal of Cardiovascular Development and Disease. 2025;12(6):214. doi:10.3390/jcdd12060214

BibTeX
@article{Brozat2025,
  author = {Brozat, Maximillian and Böckelmann, Irina and Sammito, Stefan},
  title = {Systematic Review on HRV Reference Values},
  journal = {Journal of Cardiovascular Development and Disease},
  year = {2025},
  volume = {12},
  number = {6},
  pages = {214},
  doi = {10.3390/jcdd12060214}
}
Kostenlos starten →