Laser Method for Thermal Diffusivity and Near-Infrared Absorptivity Measurements of a 310S Austenitic Stainless-Steel Block
Iron · 30.10.2026 · 1 (1) · 3
DOI: 10.3390/iron1010003 ↗Kurz gefasst
Fachartikel in der Zeitschrift Iron, online erschienen am 30.10.2026. Verfasst von Milton Sergio Fernandes de Lima und 2 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Council for Scientific and Technological Development.
Abstract (Originalsprache)
This study develops and critically assesses a modified flash-laser method for estimating, in a single arrangement, the effective thermal diffusivity and the effective near-infrared laser absorptivity of a bulk (8-mm-thick) 310S austenitic stainless steel block. Samples were irradiated with a defocused, continuous-wave ytterbium fiber laser, while thermocouples monitored the rear-face temperature response. Thermal diffusivity was estimated by fitting the normalized transient temperature curves as a function of time, whereas absorptivity was calculated using a calorimetric approach based on the measured temperature rise and the delivered laser energy. The mean thermal diffusivity obtained from nine measurements was α = (2.6 ± 0.1) × 10−6 m2/s, with acceptable fitting quality and moderate replicate scatter. This value is approximately 25% lower than handbook values for austenitic stainless steels. Three-dimensional simulations show that beam non-uniformity, heat losses, and the finite response time of the contact thermocouple bias the one-dimensional estimate by a comparable amount; the diffusivity is therefore reported as an effective, configuration-specific value. The mean effective absorptivity at 1070 nm was A = 0.30 ± 0.04 (mean ± standard deviation; expanded uncertainty of a single determination ±0.05, dominated by the manually controlled irradiation time), with improved repeatability at fixed delivered energy. This value agrees well with reported calorimetric absorptivities for metallic alloys irradiated with near-infrared lasers. The results apply to ground surfaces near room temperature (rear-face temperatures below 60 °C), and the analysis identifies the improvements needed for the method to deliver intrinsic property values.
Förderung
- National Council for Scientific and Technological Development
Zitieren
APA
Lima, M. S. F. D., Carvalho, S. M. D., & Siqueira, R. H. M. D. (2026). Laser Method for Thermal Diffusivity and Near-Infrared Absorptivity Measurements of a 310S Austenitic Stainless-Steel Block. Iron, 1(1), 3. https://doi.org/10.3390/iron1010003
Vancouver
Lima MSFD, Carvalho SMD, Siqueira RHMD. Laser Method for Thermal Diffusivity and Near-Infrared Absorptivity Measurements of a 310S Austenitic Stainless-Steel Block. Iron. 2026;1(1):3. doi:10.3390/iron1010003
BibTeX
@article{Lima2026,
author = {Lima, Milton Sergio Fernandes de and Carvalho, Sheila Medeiros de and Siqueira, Rafael Humberto Mota de},
title = {Laser Method for Thermal Diffusivity and Near-Infrared Absorptivity Measurements of a 310S Austenitic Stainless-Steel Block},
journal = {Iron},
year = {2026},
volume = {1},
number = {1},
pages = {3},
doi = {10.3390/iron1010003}
}
EUVIMED