EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Voltage Management and Coordinated Control Strategies for Medium-Voltage Flexible Interconnected Distribution Systems

Yang Yang, Zeyuan Yu, Xiaolin Liang, Shenquan Yang, Shuli Liu, Chen Wang, Haoyu Chen, Kai Liu, Huai Yang, Zihao Fang

Inventions · 17.11.2026 · 11 (6) · 125

DOI: 10.3390/inventions11060125 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Inventions, online erschienen am 17.11.2026. Verfasst von Yang Yang und 9 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Medium-voltage distribution systems that rely on flexible interconnection are facing mounting difficulty in regulating DC voltage and balancing power, a difficulty driven by the expanding presence of distributed energy resources and flexible loads. In response, this paper puts forward a coordinated control strategy for flexible interconnection devices built on multi-port modular multilevel converters (MMCs), one in which constant DC voltage control operates jointly with an adaptive droop-based scheme aimed at strengthening operational stability. The paper begins with a theoretical treatment of how the droop coefficient’s required value shifts across operating conditions, judged against two criteria: the resulting DC voltage deviation and the time needed for the system to settle. These findings then underpin a droop coefficient method governed by fuzzy logic, in which the coefficient is revised continuously in line with how far the DC voltage has drifted and how quickly that drift is changing. Under this scheme, converter terminals coordinate dynamically, power-sharing across terminals is reinforced, and disturbances are rejected more effectively even under demanding conditions. A four-port MMC interconnection system built in MATLAB/Simulink R2023b is used to test the method against terminal outages, feeder and internal converter faults, power step changes, and flow reversals; after a terminal disconnects, DC voltage overshoot drops from 3.4% to 1.7% and the recovery time shortens from 0.5 s to 0.3 s.

Zitieren

APA

Yang, Y., Yu, Z., Liang, X., Yang, S., Liu, S., Wang, C., Chen, H., Liu, K., Yang, H., & Fang, Z. (2026). Voltage Management and Coordinated Control Strategies for Medium-Voltage Flexible Interconnected Distribution Systems. Inventions, 11(6), 125. https://doi.org/10.3390/inventions11060125

Vancouver

Yang Y, Yu Z, Liang X, Yang S, Liu S, Wang C, et al. Voltage Management and Coordinated Control Strategies for Medium-Voltage Flexible Interconnected Distribution Systems. Inventions. 2026;11(6):125. doi:10.3390/inventions11060125

BibTeX
@article{Yang2026,
  author = {Yang, Yang and Yu, Zeyuan and Liang, Xiaolin and Yang, Shenquan and Liu, Shuli and Wang, Chen and Chen, Haoyu and Liu, Kai and Yang, Huai and Fang, Zihao},
  title = {Voltage Management and Coordinated Control Strategies for Medium-Voltage Flexible Interconnected Distribution Systems},
  journal = {Inventions},
  year = {2026},
  volume = {11},
  number = {6},
  pages = {125},
  doi = {10.3390/inventions11060125}
}
Kostenlos starten →