EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Multi-Channel Monitoring System with Nanosecond Resolution for Intermittent Faults in Electrical Connectors

Wanbin Ren, Yuchen Liao, Yinnan Zhang, Yuan Meng, Chao Zhang

Inventions · 17.06.2026 · 11 (3) · 64

DOI: 10.3390/inventions11030064 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Inventions, online erschienen am 17.06.2026. Verfasst von Wanbin Ren und 4 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Intermittent faults in electrical connectors refer to cases in which contact resistance exceeds a specified threshold for microseconds or less, causing transient power or signal interruptions. Accurate detection and quantitative recording of these events are important for connector reliability evaluation. In this work, an eight-channel monitoring system with nanosecond resolution for intermittent faults in electrical connectors is developed, enabling quantitative recording of intermittent events together with dynamic contact resistance (DCR) waveform acquisition. Two-stage programmable amplification is used for DCR measurement, while threshold comparison and FPGA-abased quadrature multiphase oversampling are combined to capture intermittent events. The system supports DCR measurement over 1 mΩ–10,000 mΩ with a maximum relative error of 0.41%, and provides 1.25 ns equivalent time resolution for intermittent event monitoring, with an expanded uncertainty of 0.28 ns–0.54 ns over 20 ns–10 μs. Vibration tests on high-speed connectors further demonstrate that the system captures real intermittent events under mechanical excitation and measures their durations with a maximum relative error of 0.66% relative to oscilloscope results.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Ren, W., Liao, Y., Zhang, Y., Meng, Y., & Zhang, C. (2026). Multi-Channel Monitoring System with Nanosecond Resolution for Intermittent Faults in Electrical Connectors. Inventions, 11(3), 64. https://doi.org/10.3390/inventions11030064

Vancouver

Ren W, Liao Y, Zhang Y, Meng Y, Zhang C. Multi-Channel Monitoring System with Nanosecond Resolution for Intermittent Faults in Electrical Connectors. Inventions. 2026;11(3):64. doi:10.3390/inventions11030064

BibTeX
@article{Ren2026,
  author = {Ren, Wanbin and Liao, Yuchen and Zhang, Yinnan and Meng, Yuan and Zhang, Chao},
  title = {Multi-Channel Monitoring System with Nanosecond Resolution for Intermittent Faults in Electrical Connectors},
  journal = {Inventions},
  year = {2026},
  volume = {11},
  number = {3},
  pages = {64},
  doi = {10.3390/inventions11030064}
}
Kostenlos starten →