Fachartikel in der Zeitschrift Instruments, online erschienen am 11.09.2024. Verfasst von A. Abed Abud und 39 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fermi National Accelerator Laboratory (Fermilab), a U.S. Department of Energy, Office of Science, HEP User Facility, CNPq, FAPERJ, FAPEG, and FAPESP, Brazil, CFI, IPP, and NSERC, Canada.
Abstract (Originalsprache)
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements and provide comparisons to detector simulations.
Förderung
- Fermi National Accelerator Laboratory (Fermilab), a U.S. Department of Energy, Office of Science, HEP User Facility
- CNPq, FAPERJ, FAPEG, and FAPESP, Brazil
- CFI, IPP, and NSERC, Canada
- CERN; MŠMT, Czech Republic
- ERDF, H2020-EU, and MSCA, European Union
- CNRS/IN2P3 and CEA, France
- INFN, Italy
- FCT, Portugal
Zitieren
APA
Abud, A. A., Abi, B., Acciarri, R., Acero, M. A., Adames, M. R., Adamov, G., Adamowski, M., Adams, D., Adinolfi, M., Adriano, C., Aduszkiewicz, A., Aguilar, J., Aimard, B., Akbar, F., Allison, K., Monsalve, S. A., Alrashed, M., Alton, A., Alvarez, R., …, & Ashkenazi, A. (2024). Performance of a Modular Ton-Scale Pixel-Readout Liquid Argon Time Projection Chamber. Instruments, 8(3), 41. https://doi.org/10.3390/instruments8030041
Vancouver
Abud AA, Abi B, Acciarri R, Acero MA, Adames MR, Adamov G, et al. Performance of a Modular Ton-Scale Pixel-Readout Liquid Argon Time Projection Chamber. Instruments. 2024;8(3):41. doi:10.3390/instruments8030041
BibTeX
@article{Abud2024,
author = {Abud, A. Abed and Abi, B. and Acciarri, R. and Acero, M. A. and Adames, M. R. and Adamov, G. and Adamowski, M. and Adams, D. and Adinolfi, M. and Adriano, C. and Aduszkiewicz, A. and Aguilar, J. and Aimard, B. and Akbar, F. and Allison, K. and Monsalve, S. Alonso and Alrashed, M. and Alton, A. and Alvarez, R. and Alves, T. and Amar, H. and Amedo, P. and Anderson, J. and Andrade, D. A. and Andreopoulos, C. and Andreotti, M. and Andrews, M. P. and Andrianala, F. and Andringa, S. and Anfimov, N. and Ankowski, A. and Antoniassi, M. and Antonova, M. and Antoshkin, A. and Aranda-Fernandez, A. and Arellano, L. and Diaz, E. Arrieta and Arroyave, M. A. and Asaadi, J. and Ashkenazi, A.},
title = {Performance of a Modular Ton-Scale Pixel-Readout Liquid Argon Time Projection Chamber},
journal = {Instruments},
year = {2024},
volume = {8},
number = {3},
pages = {41},
doi = {10.3390/instruments8030041}
}
EUVIMED