A Rapid, Non-Destructive Method to Detect Counterfeit Integrated Circuits Using a Resonant Cavity System
Instruments · 07.07.2024 · 8 (3) · 37
DOI: 10.3390/instruments8030037 ↗Kurz gefasst
Fachartikel in der Zeitschrift Instruments, online erschienen am 07.07.2024. Verfasst von Aditya Nechiyil und 2 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Air Force Research Laboratory.
Abstract (Originalsprache)
The counterfeiting of integrated circuits (ICs) has been a growing issue. Current available methods used to detect counterfeit ICs can be expensive, imprecise, and time-consuming. This paper explores the resonant cavity system: a non-contact, non-destructive method to rapidly differentiate counterfeit ICs from authentic ones. The system captures a unique signature of an IC placed inside it. Data were captured for ICs of various technologies and authenticities. The data included return loss values captured at various transverse electric (TE) modes between 2.8 GHz and 6 GHz. This allowed for the comparison of the effectiveness of the various TE modes in being able to distinguish ICs. The resonant cavity system was able to distinguish most of the ICs at higher TE modes.
Förderung
- Air Force Research Laboratory
Zitieren
APA
Nechiyil, A., Lee, R., & Chapman, G. (2024). A Rapid, Non-Destructive Method to Detect Counterfeit Integrated Circuits Using a Resonant Cavity System. Instruments, 8(3), 37. https://doi.org/10.3390/instruments8030037
Vancouver
Nechiyil A, Lee R, Chapman G. A Rapid, Non-Destructive Method to Detect Counterfeit Integrated Circuits Using a Resonant Cavity System. Instruments. 2024;8(3):37. doi:10.3390/instruments8030037
BibTeX
@article{Nechiyil2024,
author = {Nechiyil, Aditya and Lee, Robert and Chapman, Gregg},
title = {A Rapid, Non-Destructive Method to Detect Counterfeit Integrated Circuits Using a Resonant Cavity System},
journal = {Instruments},
year = {2024},
volume = {8},
number = {3},
pages = {37},
doi = {10.3390/instruments8030037}
}