Hardware Design of a High Dynamic Range Radio Frequency (RF) Harmonic Measurement System
Instruments · 19.08.2018 · 2 (3) · 16
DOI: 10.3390/instruments2030016 ↗Kurz gefasst
Fachartikel in der Zeitschrift Instruments, online erschienen am 19.08.2018. Verfasst von Ram M. Narayanan und 4 weiteren Autor:innen. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Army Research Office.
Abstract (Originalsprache)
Radio frequency (RF) circuit elements that are traditionally considered to be linear frequently exhibit nonlinear properties that affect the intended operation of many other RF systems. Devices such as RF connectors, antennas, attenuators, resistors, and dissimilar metal junctions generate nonlinear distortion that degrades primary RF system performance. The communications industry is greatly affected by these unintended and unexpected nonlinear distortions. The high transmit power and tight channel spacing of the communication channel makes communications very susceptible to nonlinear distortion. To minimize nonlinear distortion in RF systems, specialized circuits are required to measure the low level nonlinear distortions created from traditionally linear devices, i.e., connectors, cables, antennas, etc. Measuring the low-level nonlinear distortion is a difficult problem. The measurement system requires the use of high power probe signals and the capability to measure very weak nonlinear distortions. Measuring the weak nonlinear distortion becomes increasingly difficult in the presence of higher power probe signals, as the high power probe signal generates distortion products in the measurement system. This paper describes a circuit design architecture that achieves 175 dB of dynamic range which can be used to measure low level harmonic distortion from various passive RF circuit elements.
Förderung
- Army Research Office
Zitieren
APA
Narayanan, R. M., Gallagher, K. A., Mazzaro, G. J., Martone, A. F., & Sherbondy, K. D. (2018). Hardware Design of a High Dynamic Range Radio Frequency (RF) Harmonic Measurement System. Instruments, 2(3), 16. https://doi.org/10.3390/instruments2030016
Vancouver
Narayanan RM, Gallagher KA, Mazzaro GJ, Martone AF, Sherbondy KD. Hardware Design of a High Dynamic Range Radio Frequency (RF) Harmonic Measurement System. Instruments. 2018;2(3):16. doi:10.3390/instruments2030016
BibTeX
@article{Narayanan2018,
author = {Narayanan, Ram M. and Gallagher, Kyle A. and Mazzaro, Gregory J. and Martone, Anthony F. and Sherbondy, Kelly D.},
title = {Hardware Design of a High Dynamic Range Radio Frequency (RF) Harmonic Measurement System},
journal = {Instruments},
year = {2018},
volume = {2},
number = {3},
pages = {16},
doi = {10.3390/instruments2030016}
}