Smartphone-Based Quantitative Measurement of Capillary Refill Time
Instruments · 03.03.2026 · 10 (1) · 15
DOI: 10.3390/instruments10010015 ↗Kurz gefasst
Fachartikel in der Zeitschrift Instruments, online erschienen am 03.03.2026. Verfasst von Chiho Miyazawa und 6 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Capillary refill time (CRT) is widely used in pediatric and emergency medicine as an indicator of peripheral circulation. CRT is defined as the time required for the skin to return to its original color after external compression is applied and then released. In current clinical practice, however, CRT assessment remains qualitative and relies heavily on the magnitude and consistency of compression applied by the measurer, as well as on subjective visual color perception, which together result in limited measurement reliability. To improve measurement reliability, several quantitative CRT measurement devices have been developed. Nevertheless, these devices are dedicated specifically to CRT measurement, which limits their versatility and complicates clinical implementation. In this study, we developed a simple and quantitative CRT measurement method using a smartphone. Based on skin color changes captured by the rear camera, we proposed a method to assess the adequacy of the applied compression force and implemented an application to calculate CRT. In addition, we investigated an algorithm to reduce the influence of pulse waves observed in the post-release waveform, enabling more stable CRT estimation. Furthermore, a dedicated smartphone case was designed to immobilize the finger during measurement, thereby improving measurement reliability. The feasibility of the proposed method was evaluated by examining agreement with a previously developed CRT measurement device and by assessing intraexaminer reliability, confirming its effectiveness.
Zitieren
APA
Miyazawa, C., Shinozaki, M., Miwa, Y., Karasawa, S., Nakada, T., Nomura, Y., & Nakaguchi, T. (2026). Smartphone-Based Quantitative Measurement of Capillary Refill Time. Instruments, 10(1), 15. https://doi.org/10.3390/instruments10010015
Vancouver
Miyazawa C, Shinozaki M, Miwa Y, Karasawa S, Nakada T, Nomura Y, et al. Smartphone-Based Quantitative Measurement of Capillary Refill Time. Instruments. 2026;10(1):15. doi:10.3390/instruments10010015
BibTeX
@article{Miyazawa2026,
author = {Miyazawa, Chiho and Shinozaki, Masayoshi and Miwa, Yayoi and Karasawa, Satoshi and Nakada, Taka-aki and Nomura, Yukihiro and Nakaguchi, Toshiya},
title = {Smartphone-Based Quantitative Measurement of Capillary Refill Time},
journal = {Instruments},
year = {2026},
volume = {10},
number = {1},
pages = {15},
doi = {10.3390/instruments10010015}
}
EUVIMED