EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Characterization of the Extraction System of Supersonic Gas Curtain-Based Ionization Profile Monitor for FLASH Proton Therapy

Farhana Thesni Mada Parambil, Milaan Patel, Narender Kumar, Bharat Singh Rawat, William Butcher, Tony Price, Carsten P. Welsch

Instruments · 2026

DOI: 10.3390/instruments10010004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Instruments, 2026. Verfasst von Farhana Thesni Mada Parambil und 6 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

FLASH radiotherapy requires real-time, non-invasive beam monitoring systems capable of operating under ultra-high dose rate (UHDR) conditions without perturbing the therapeutic beam. In this work, we characterized the extraction system of Supersonic Gas Curtain-based Ionization Profile Monitor (SGC-IPM) for its capabilities as a transverse beam profile and position monitor for FLASH protons. The monitor utilizes a tilted gas curtain intersected by the incident beam, leading to the generation of ions that are extracted through a tailored electrostatic field, and detected using a two stage microchannel plate (MCP) coupled to a phosphor screen and CMOS camera. CST Studio Suite was employed to conduct electrostatic and particle tracking simulations evaluating the ability of the extraction system to measure both beam profile and position. The ion interface, at the interaction region of proton beam and gas curtain, was modeled with realistic proton beam parameters and uniform gas curtain density distributions. The ion trajectory was tracked to evaluate the performance across multiple beam sizes. The simulations suggest that the extraction system can reconstruct transverse beam profiles for different proton beam sizes. Simulations also supported the system’s capability as a beam position monitor within the boundary defined by the beam size, the dimensions of the extraction system, and the height of the gas curtain. Some simulation results were benchmarked against experimental data of 28 MeV proton beam with 70 nA average beam current. This study will further help to optimize the design of the extraction system to facilitate the integration of SGC-IPM in medical accelerators.

Zitieren

APA

Parambil, F. T. M., Patel, M., Kumar, N., Rawat, B. S., Butcher, W., Price, T., & Welsch, C. P. (2026). Characterization of the Extraction System of Supersonic Gas Curtain-Based Ionization Profile Monitor for FLASH Proton Therapy. Instruments. https://doi.org/10.3390/instruments10010004

Vancouver

Parambil FTM, Patel M, Kumar N, Rawat BS, Butcher W, Price T, et al. Characterization of the Extraction System of Supersonic Gas Curtain-Based Ionization Profile Monitor for FLASH Proton Therapy. Instruments. 2026. doi:10.3390/instruments10010004

BibTeX
@article{Parambil2026,
  author = {Parambil, Farhana Thesni Mada and Patel, Milaan and Kumar, Narender and Rawat, Bharat Singh and Butcher, William and Price, Tony and Welsch, Carsten P.},
  title = {Characterization of the Extraction System of Supersonic Gas Curtain-Based Ionization Profile Monitor for FLASH Proton Therapy},
  journal = {Instruments},
  year = {2026},
  doi = {10.3390/instruments10010004}
}
Kostenlos starten →