EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

In-Trap CO2 Accumulation as a Quantitative Index of Termite Abundance: Design and Evaluation of a Networked Multi-Gas Sensing System

Hangjun Wang, Hao Huang, Shan Wu, Lujun Lin

Insects · 15.11.2026 · 17 (11) · 1192

DOI: 10.3390/insects17111192 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Insects, online erschienen am 15.11.2026. Verfasst von Hangjun Wang und 3 weiteren Autor:innen. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Zhejiang Provincial Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Termite monitoring traps signal only presence or absence, leaving treatment decisions blind to infestation size. Termites respire CO2, so the gas accumulating inside a trap could in principle report how many workers it holds; existing work, however, relates CO2 to colony biomass rather than to termite number. Here we present a low-cost networked sensing system that records CO2, a metal-oxide (MOx) methane channel, temperature, and humidity inside sealed termite traps, and we use it to establish, to our knowledge, the first in-trap dose–response indexed to termite number rather than biomass. Across three temporally disjoint batches, each with its own blank control, eight single-chamber loads of 105–500 Coptotermes formosanus workers were tested under controlled laboratory conditions; net 24 h CO2 accumulation rose near-linearly with worker number (6.75 ± 0.95 ppm termite−1 24 h−1, R2 = 0.893) and retained leave-one-out skill (Q2 = 0.80), while a second, metal-oxide CH4 channel ordered the chambers consistently (ρ = 0.970) as a device response rather than a methane flux. We report this as a descriptive laboratory dose–response for worker number rather than as a validated abundance estimator: with one chamber per load, termite number is confounded with chamber, node and colony differences, and the calibration is not yet transferable between batches (11.9–21.4% overprediction), whereas the sensor noise floor corresponded to fewer than ten termites. In the eight laboratory chambers tested, the 59.8 ppm presence threshold was crossed within 0.16–1.45 h (10–87 min) of sealing; four-hour triage and grading abundance at the moment of detection remain potential applications that require site- and season-specific calibration and replicated field validation.

Förderung

  • Zhejiang Provincial Natural Science Foundation of China

Zitieren

APA

Wang, H., Huang, H., Wu, S., & Lin, L. (2026). In-Trap CO2 Accumulation as a Quantitative Index of Termite Abundance: Design and Evaluation of a Networked Multi-Gas Sensing System. Insects, 17(11), 1192. https://doi.org/10.3390/insects17111192

Vancouver

Wang H, Huang H, Wu S, Lin L. In-Trap CO2 Accumulation as a Quantitative Index of Termite Abundance: Design and Evaluation of a Networked Multi-Gas Sensing System. Insects. 2026;17(11):1192. doi:10.3390/insects17111192

BibTeX
@article{Wang2026,
  author = {Wang, Hangjun and Huang, Hao and Wu, Shan and Lin, Lujun},
  title = {In-Trap CO2 Accumulation as a Quantitative Index of Termite Abundance: Design and Evaluation of a Networked Multi-Gas Sensing System},
  journal = {Insects},
  year = {2026},
  volume = {17},
  number = {11},
  pages = {1192},
  doi = {10.3390/insects17111192}
}
Kostenlos starten →