EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Linear and Nonlinear Performance Evaluation of Composite Space Truss Decks in Cable-Stayed Bridges: Suez Canal Bridge Case Study

Hesham Fawzy Shaaban, Ayman El-Zohairy, Mohamed Atabi

Infrastructures · 25.03.2026 · 11 (4) · 112

DOI: 10.3390/infrastructures11040112 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Infrastructures, online erschienen am 25.03.2026. Verfasst von Hesham Fawzy Shaaban und 2 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates the structural performance of a novel composite space truss deck system as an alternative to the conventional steel box girder in cable-stayed bridges. Using the Suez Canal Bridge as a benchmark, comprehensive linear and nonlinear finite element analyses were performed to evaluate the global behavior of both deck configurations under dead, live, wind, and temperature loads. The proposed system consists of a three-dimensional square-on-square truss acting compositely with a 25 cm reinforced concrete slab, designed to optimize stiffness and material efficiency. The results revealed that the composite space truss deck achieved a 5–7% reduction in mid-span deflection under live loading and a 6% increase in torsional rigidity compared with the steel box girder, while maintaining comparable self-weight (490 kg/m2 versus 480 kg/m2). The influence of geometric nonlinearity was moderate, 6.56% for the space truss and 1.64% for the box girder, whereas temperature variations of ±30 °C induced up to a 25.3% change in mid-span deflection, highlighting the space truss’s higher thermal sensitivity. Parametric analyses demonstrated that increasing the truss depth from 2.5 m to 4.0 m enhanced global stiffness by 15%, and using lightweight concrete reduced mid-span deflection by 30%. Overall, the composite space truss system offers superior stiffness-to-weight efficiency, substantial steel savings (two-thirds less), and competitive construction economy, establishing it as a promising solution for medium- and long-span cable-stayed bridges.

Zitieren

APA

Shaaban, H. F., El-Zohairy, A., & Atabi, M. (2026). Linear and Nonlinear Performance Evaluation of Composite Space Truss Decks in Cable-Stayed Bridges: Suez Canal Bridge Case Study. Infrastructures, 11(4), 112. https://doi.org/10.3390/infrastructures11040112

Vancouver

Shaaban HF, El-Zohairy A, Atabi M. Linear and Nonlinear Performance Evaluation of Composite Space Truss Decks in Cable-Stayed Bridges: Suez Canal Bridge Case Study. Infrastructures. 2026;11(4):112. doi:10.3390/infrastructures11040112

BibTeX
@article{Shaaban2026,
  author = {Shaaban, Hesham Fawzy and El-Zohairy, Ayman and Atabi, Mohamed},
  title = {Linear and Nonlinear Performance Evaluation of Composite Space Truss Decks in Cable-Stayed Bridges: Suez Canal Bridge Case Study},
  journal = {Infrastructures},
  year = {2026},
  volume = {11},
  number = {4},
  pages = {112},
  doi = {10.3390/infrastructures11040112}
}
Kostenlos starten →