EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Objective Assessment of Orofacial Muscle Strength: Validation of an Alternative Low-Cost Measurement Device

Eduardo J. Correa, James Curtis, Laura Rodriguez Alcalá, Juan Antonio Ibañez-Rodriguez, Marta Morato-Galán, Gislaine Aparecida Folha, Cristina Rodriguez Alcalá, María Teresa García Iriarte, Guillermo Plaza, Carlos O'Connor-Reina

International Journal of Orofacial Myology and Myofunctional Therapy · 2025

DOI: 10.3390/ijom51020009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Orofacial Myology and Myofunctional Therapy, 2025. Verfasst von Eduardo J. Correa und 9 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Accurate measurement of orofacial muscle strength is essential for phenotyping patients with obstructive sleep apnea (OSA), and particularly those with hypotonic phenotypes. High costs associated with gold standard devices such as the Iowa Oral Performance Instrument (IOPI®) limit their clinical use. This study aims to validate the Sandway® manometer, a low-cost alternative to the IOPI®, by comparing its performance against the IOPI® and the Tongue Digital Spoon (TDS) in both laboratory and clinical settings.

Methods

We conducted a two-phase study. In the laboratory phase, pressure readings from the IOPI® and Sandway® devices were compared using standardized force application methods. In the clinical phase, 60 patients with moderate-to-severe untreated OSA underwent orofacial strength evaluation using IOPI®, Sandway®, and TDS devices. Intraclass Correlation Coefficient (ICC), Bland–Altman analysis, and Pearson correlation were used to assess reliability and agreement.

Results

The Sandway® showed excellent reliability for anterior tongue and lip strength measures (ICC = 0.978). Bland–Altman plots revealed minimal bias and narrow limits of agreement compared to the IOPI®, indicating strong agreement for both tongue and lip measurements. A high correlation was also observed between Sandway® and TDS results (r = 0.863, p < 0.001), supporting secondary validation.

Conclusions

The Sandway® manometer demonstrates high reliability and strong agreement with gold standard instruments, representing a valid, accessible alternative for objective assessment of orofacial muscle strength in clinical practice.

Zitieren

APA

Correa, E. J., Curtis, J., Alcalá, L. R., Ibañez-Rodriguez, J. A., Morato-Galán, M., Folha, G. A., Alcalá, C. R., Iriarte, M. T. G., Plaza, G., & O'Connor-Reina, C. (2025). Objective Assessment of Orofacial Muscle Strength: Validation of an Alternative Low-Cost Measurement Device. International Journal of Orofacial Myology and Myofunctional Therapy. https://doi.org/10.3390/ijom51020009

Vancouver

Correa EJ, Curtis J, Alcalá LR, Ibañez-Rodriguez JA, Morato-Galán M, Folha GA, et al. Objective Assessment of Orofacial Muscle Strength: Validation of an Alternative Low-Cost Measurement Device. International Journal of Orofacial Myology and Myofunctional Therapy. 2025. doi:10.3390/ijom51020009

BibTeX
@article{Correa2025,
  author = {Correa, Eduardo J. and Curtis, James and Alcalá, Laura Rodriguez and Ibañez-Rodriguez, Juan Antonio and Morato-Galán, Marta and Folha, Gislaine Aparecida and Alcalá, Cristina Rodriguez and Iriarte, María Teresa García and Plaza, Guillermo and O'Connor-Reina, Carlos},
  title = {Objective Assessment of Orofacial Muscle Strength: Validation of an Alternative Low-Cost Measurement Device},
  journal = {International Journal of Orofacial Myology and Myofunctional Therapy},
  year = {2025},
  doi = {10.3390/ijom51020009}
}
Kostenlos starten →