Nanosecond Infrared Laser Sampling of Mouse and Human Liver Tissues for LC-MS/MS Analysis of Bile Acids
International Journal of Molecular Sciences · 20.05.2026 · 27 (10) · 4572
DOI: 10.3390/ijms27104572 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Molecular Sciences, online erschienen am 20.05.2026. Verfasst von Marceline M Fuh und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biochemistry and Molecular Cell Biology, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany. Hauptthemen laut MEDLINE: Bile Acids and Salts, Liver, Tandem Mass Spectrometry, Liquid Chromatography-Mass Spectrometry. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
Accurate quantification of bile acids is vital as they are potential biomarkers for several diseases. To solubilize bile acids from tissues, homogenization is required, typically performed using mechanical methods such as the TissueLyser method. Drawbacks like available tissue amount and low abundance of bile acids interfere with the analysis. We aim to establish a nanosecond infrared laser (NIRL) as a possible tissue homogenization tool to circumvent problems associated with limited sample amounts for research and to target low abundance bile acids. We quantify bile acids from mouse and human liver tissues comparing both the classic TissueLyser and the NIRL methods for homogenization prior to LC-MS/MS analysis. The applicability of our approach is tested using mice lacking Cyp2c70, a well-established mouse model with an altered bile acid composition compared to wild type mice. We found the NIRL method to require an almost 14 times smaller starting tissue amount than the TissueLyser method. The NIRL is also comparable to the TissueLyser for high abundance bile acids. While the TissueLyser provides efficient mechanical homogenization, the NIRL potentially enables quantification of low abundance bile acids. The well-established biological differences in bile acid profiles from the Cyp2c70 knockout mouse model were also observed with NIRL homogenization. These results show that the NIRL is potentially useful as smaller tissue amounts are required for analysis and low abundance bile acids are quantifiable.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biochemistry and Molecular Cell Biology, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany.
- Section Mass Spectrometry and Proteomics, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany.
- Department of General, Visceral and Thoracic Surgery, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany.
ORCID-Profile: Jan Hahn, Markus Heine, Joerg Heeren
Förderung
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Fuh, M. M., Hahn, J., Heine, M., Evangelakos, I., Scheja, L., Mann, O., Worthmann, A., Schlüter, H., & Heeren, J. (2026). Nanosecond Infrared Laser Sampling of Mouse and Human Liver Tissues for LC-MS/MS Analysis of Bile Acids. International Journal of Molecular Sciences, 27(10), 4572. https://doi.org/10.3390/ijms27104572
Vancouver
Fuh MM, Hahn J, Heine M, Evangelakos I, Scheja L, Mann O, et al. Nanosecond Infrared Laser Sampling of Mouse and Human Liver Tissues for LC-MS/MS Analysis of Bile Acids. International Journal of Molecular Sciences. 2026;27(10):4572. doi:10.3390/ijms27104572
BibTeX
@article{Fuh2026,
author = {Fuh, Marceline M and Hahn, Jan and Heine, Markus and Evangelakos, Ioannis and Scheja, Ludger and Mann, Oliver and Worthmann, Anna and Schlüter, Hartmut and Heeren, Joerg},
title = {Nanosecond Infrared Laser Sampling of Mouse and Human Liver Tissues for LC-MS/MS Analysis of Bile Acids},
journal = {International Journal of Molecular Sciences},
year = {2026},
volume = {27},
number = {10},
pages = {4572},
doi = {10.3390/ijms27104572}
}
EUVIMED