Quantification Revisited: What qPCR Efficiency Models Reveal About Data Analysis Integrity
International Journal of Molecular Sciences · 02.03.2026 · 27 (5) · 2337
DOI: 10.3390/ijms27052337 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift International Journal of Molecular Sciences, online erschienen am 02.03.2026. Verfasst von Stephen A Bustin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Medical Technology Research Centre, Faculty of Health, Education, Medicine and Social Care, Anglia Ruskin University, Chelmsford CM1 1SQ, UK. Hauptthemen laut MEDLINE: Real-Time Polymerase Chain Reaction. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Amplification efficiency is one of the key parameters in quantitative real-time PCR, as it directly influences the accuracy of both absolute and relative quantification. Amplification efficiency, the fold increase per cycle, is affected by oligonucleotide design, reaction chemistry, sample and template properties, and instrument performance. Consequently, it differs between samples, assays and experimental runs. Although methods for estimating the amplification efficiency have been available for more than two decades, most published qPCR studies continue to assume equal and ideal efficiency across assays. This simplifying assumption introduces efficiency- and expression-dependent error into relative expression and fold-change analyses, contributing to the poor reproducibility observed in many PCR-based studies. This review examines the role of the amplification efficiency in qPCR quantification; the consequences of ignoring, assuming or misapplying efficiency; and the practical implications for data interpretation. The review also considers the development of efficiency estimation models and their implications for contemporary analytical approaches, including emerging data-driven methods for amplification curve analyses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Medical Technology Research Centre, Faculty of Health, Education, Medicine and Social Care, Anglia Ruskin University, Chelmsford CM1 1SQ, UK.
- Department of Medical Biology, Amsterdam UMC, Location AMC, Meibergdreef 15, 1105 AZ Amsterdam, The Netherlands.
- Animal Physiology & Immunology, School of Life Sciences, Technical University of Munich, Liesel-Beckmann-Straße 1, 85354 Freising, Germany.
- Institute of Biotechnology CAS, Czech Academy of Science, 252 50 Prague, Czech Republic.
ORCID-Profile: Stephen A Bustin, Maurice J B van den Hoff, Michael W Pfaffl, Mikael Kubista
Zitieren
APA
Bustin, S. A., van den Hoff, M. J. B., Pfaffl, M. W., Kubista, M., & Ruijter, J. M. (2026). Quantification Revisited: What qPCR Efficiency Models Reveal About Data Analysis Integrity. International Journal of Molecular Sciences, 27(5), 2337. https://doi.org/10.3390/ijms27052337
Vancouver
Bustin SA, van den Hoff MJB, Pfaffl MW, Kubista M, Ruijter JM. Quantification Revisited: What qPCR Efficiency Models Reveal About Data Analysis Integrity. International Journal of Molecular Sciences. 2026;27(5):2337. doi:10.3390/ijms27052337
BibTeX
@article{Bustin2026,
author = {Bustin, Stephen A and van den Hoff, Maurice J B and Pfaffl, Michael W and Kubista, Mikael and Ruijter, Jan M},
title = {Quantification Revisited: What qPCR Efficiency Models Reveal About Data Analysis Integrity},
journal = {International Journal of Molecular Sciences},
year = {2026},
volume = {27},
number = {5},
pages = {2337},
doi = {10.3390/ijms27052337}
}
EUVIMED