Fachartikel in der Zeitschrift International Journal of Molecular Sciences, 2025. Verfasst von Katarzyna Fendrych und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical Chemistry and Biochemistry, Faculty of Materials Science and Ceramics, AGH University of Krakow, al. A. Mickiewicza 30, 30-0…. Hauptthemen laut MEDLINE: Zeolites, Carbon, Nickel, Electrochemical Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Centre, National Science Centre, Poland.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This work presents the fabrication and analytical application of nanostructured Ni-zeolite (NiZY) and carbon nanohorns (CNHs) modified glassy carbon electrode (NiZY/CNHs-GCE) in the differential pulse voltammetric (DPV) determination of vitamin B2 (VB2) molecules. The synergistic combination of NiZY and CNHs significantly enhances the electrochemical performance of the sensor, as confirmed by structural, textural, morphological, and electrochemical studies. The redox behavior of VB2 on NiZY/CNHs-GCE was found to be adsorption-controlled, involving a two-electron, two-proton reversible reduction process. Under optimized conditions, the DPV response of NiZY/CNHs-GCEs in McIlvaine buffer solution (pH 3.4) exhibited a linearity in the VB2 concentration range of 0.01 to 0.20 mg L−1 (r = 0.9993) with a detection limit of 3.2 µg L−1 (8.6 × 10−9 mol L−1). Furthermore, well-resolved reduction peaks of vitamins B2 and B9 (VB9) enabled their simultaneous and selective detection, with linear ranges of 0.01 to 0.20 mg L−1 for VB2 and 0.01 to 0.16 mg L−1 for VB9. The proposed analytical method, characterized by high selectivity and robustness, was successfully applied in the determination of both vitamins in commercially available dietary supplements, achieving relative errors within −6.2% to 2.7%.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ZeolitesCarbonNickelElectrochemical TechniquesNanostructuresVitamin B ComplexRiboflavinElectrodesLimit of DetectionOxidation-Reduction

Stichwörter der Autor:innen

carbon nanohornsdietary supplementsvitamin B2voltammetryzeolite Yzeolite-modified electrode

Substanzen

ZeolitesCarbonNickelVitamin B ComplexRiboflavin

Autor:innen und Institutionen

  • Department of Analytical Chemistry and Biochemistry, Faculty of Materials Science and Ceramics, AGH University of Krakow, al. A. Mickiewicza 30, 30-059 Kraków, Poland.

ORCID-Profile: Katarzyna Fendrych, Joanna Smajdor, Robert Piech, Bogusław Baś

Förderung

  • National Science Centre
  • National Science Centre, Poland

Zitieren

APA

Fendrych, K., Nyrka, J., Smajdor, J., Piech, R., & Baś, B. (2025). Nanostructured Ni-Zeolite Y and Carbon Nanohorns Electrode for Sensitive Electrochemical Determination of B-Group Vitamins. International Journal of Molecular Sciences. https://doi.org/10.3390/ijms262110469

Vancouver

Fendrych K, Nyrka J, Smajdor J, Piech R, Baś B. Nanostructured Ni-Zeolite Y and Carbon Nanohorns Electrode for Sensitive Electrochemical Determination of B-Group Vitamins. International Journal of Molecular Sciences. 2025. doi:10.3390/ijms262110469

BibTeX
@article{Fendrych2025,
  author = {Fendrych, Katarzyna and Nyrka, Justyna and Smajdor, Joanna and Piech, Robert and Baś, Bogusław},
  title = {Nanostructured Ni-Zeolite Y and Carbon Nanohorns Electrode for Sensitive Electrochemical Determination of B-Group Vitamins},
  journal = {International Journal of Molecular Sciences},
  year = {2025},
  doi = {10.3390/ijms262110469}
}
Kostenlos starten →