PAM-Independent Cas12a Detection of Specific LAMP Products by Targeting Amplicon Loops
International Journal of Molecular Sciences · 2025
DOI: 10.3390/ijms26168014 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Molecular Sciences, 2025. Verfasst von Konstantin G Ptitsyn und 7 weiteren Autor:innen. Beteiligte Einrichtung: V.N. Orekhovich Institute of Biomedical Chemistry, 10 Pogodinskaya St., 119121 Moscow, Russia. Hauptthemen laut MEDLINE: Nucleic Acid Amplification Techniques, Bacterial Proteins, CRISPR-Associated Proteins, Endodeoxyribonucleases. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Program for Basic Research in the Russian Federation for a long-term period (2021-2030), Russian Federation.
Abstract (Originalsprache)
A straightforward approach is suggested to selectively recognize specific products of loop-mediated isothermal amplification (LAMP) with the Cas12a nuclease without a need for a protospacer adjacent motif (PAM) in the sequence of LAMP amplicons (LAMPlicons). This strategy is based on the presence of single-stranded DNA loops in LAMPlicons and the ability of Cas12a to be trans-activated via the binding of guide RNA (gRNA) to single-stranded DNA in the absence of PAM. The approach feasibility is demonstrated on Clavibacter species—multiple bacterial plant pathogens that cause harmful diseases in agriculturally important plants. For Clavibacter species, the detection sensitivity of the developed PAM-independent LAMP/Cas12a system was determined by that of LAMP. The overall detection selectivity was enhanced by the Cas12a analysis of LAMPlicons. It was shown that the LAMP/Cas12a detection system can be fine-tuned by carefully designing gRNA to selectively distinguish C. sepedonicus from other Clavibacter species based on single nucleotide substitutions in the targeted LAMPlicon loop. The suggested loop-based Cas12a analysis of LAMPlicons was compatible with the format of a single test tube assay with the option of naked-eye detection. The findings broaden the palette of approaches to designing PAM-independent LAMP/Cas12a detection systems with potential for on-site testing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- V.N. Orekhovich Institute of Biomedical Chemistry, 10 Pogodinskaya St., 119121 Moscow, Russia.
- Chemistry Faculty, M.V. Lomonosov Moscow State University, 1/3 Lenin Hills, 119991 Moscow, Russia.
ORCID-Profile: Konstantin G Ptitsyn, Svetlana A Khmeleva, Daria D Morozova, Elena V Suprun, Sergey P Radko
Förderung
- Program for Basic Research in the Russian Federation for a long-term period (2021-2030)
- Russian Federation
Zitieren
APA
Ptitsyn, K. G., Kurbatov, L. K., Khmeleva, S. A., Morozova, D. D., Timoshenko, O. S., Suprun, E. V., Radko, S. P., & Lisitsa, A. V. (2025). PAM-Independent Cas12a Detection of Specific LAMP Products by Targeting Amplicon Loops. International Journal of Molecular Sciences. https://doi.org/10.3390/ijms26168014
Vancouver
Ptitsyn KG, Kurbatov LK, Khmeleva SA, Morozova DD, Timoshenko OS, Suprun EV, et al. PAM-Independent Cas12a Detection of Specific LAMP Products by Targeting Amplicon Loops. International Journal of Molecular Sciences. 2025. doi:10.3390/ijms26168014
BibTeX
@article{Ptitsyn2025,
author = {Ptitsyn, Konstantin G and Kurbatov, Leonid K and Khmeleva, Svetlana A and Morozova, Daria D and Timoshenko, Olga S and Suprun, Elena V and Radko, Sergey P and Lisitsa, Andrey V},
title = {PAM-Independent Cas12a Detection of Specific LAMP Products by Targeting Amplicon Loops},
journal = {International Journal of Molecular Sciences},
year = {2025},
doi = {10.3390/ijms26168014}
}
EUVIMED