EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Biocompatibility Evaluation of Surface-Modified Orthodontic Wires Using Graphene Layer

Joanna Rygas, Maria Szymonowicz iD, Agnieszka Rusak iD, Magdalena Wawrzyńska, Piotr Kuropka iD, Vitalii Boiko iD, Bartosz Mielan iD, Dariusz Hreniak iD, Maciej Dobrzyński iD

International Journal of Molecular Sciences · 2025

DOI: 10.3390/ijms26167804 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Molecular Sciences, 2025. Verfasst von Joanna Rygas und 8 weiteren Autor:innen. Beteiligte Einrichtung: Dental Practice, Staszica Str. 46A, 98-300 Wielun, Poland. Hauptthemen laut MEDLINE: Graphite, Materials Testing, Orthodontic Wires, Coated Materials, Biocompatible. Die Arbeit nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wroclaw Medical University (Wroclaw, Poland).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The biocompatibility of orthodontic archwires is crucial for ensuring patient safety and the long-term success of orthodontic treatment. This study evaluated the biocompatibility of stainless steel (SS) and nickel–titanium (Ni-Ti) orthodontic archwires, as well as stainless steel metal brackets, before and after the application of a graphene coating. The assessment was based on the materials’ effects on a fibroblast cell line and on the development of a foetal chicken egg embryo. Fibroblasts that had been in temporary contact with steel and NiTi archwires after CW-CVD (cold wall chemical vapour deposition) treatment exhibited changes in morphology in the presence of the material. The materials exhibited moderate cytotoxicity. For metal brackets, the treated samples caused stronger cytotoxic changes in the culture. Unlike graphene-coated implants, where cells were found to directly adhere to the surface, the embryonic tissues did not treat the non-graphene-coated implants as an adhesive material. This study suggests that depositing carbon-based coatings, including graphene, on stainless steel archwires may reduce the cytotoxicity of orthodontic components. Using graphene increases adhesion of the implant surface to membrane-derived cells and the embryonic yolk and does not inhibit the further development of the chicken egg embryo.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GraphiteMaterials TestingOrthodontic WiresCoated Materials, BiocompatibleBiocompatible MaterialsAnimalsChick EmbryoStainless SteelFibroblastsSurface PropertiesNickelTitaniumCell LineCell Adhesion

Stichwörter der Autor:innen

CW-CVDNiTi archwires stainless steel archwiresbiocompatibilitycytotoxicitygraphene

Substanzen

GraphiteStainless SteelCoated Materials, BiocompatibleNickelTitaniumBiocompatible Materialstitanium nickelide

Autor:innen und Institutionen

  • Dental Practice, Staszica Str. 46A, 98-300 Wielun, Poland.
  • Pre-Clinical Research Centre, Wroclaw Medical University, Bujwida Str. 44, 50-368 Wroclaw, Poland.
  • Division of Histology and Embryology, Department of Human Morphology and Embryology, Faculty of Medicine, Wroclaw Medical University, Chalubinskiego Str. 6a, 50-368 Wroclaw, Poland.
  • Division of Histology and Embryology, Department of Biostructure and Animal Physiology, Faculty of Veterinary Medicine, Wroclaw University of Environmental and Life Sciences, Norwida Str. 25, 50-375 Wroclaw, Poland.
  • Institute of Low Temperature and Structure Research, Polish Academy of Sciences, Okolna Str. 2, 50-422 Wrocław, Poland.
  • Institute of Physics of the National Academy of Science of Ukraine, Prospect Nauky Str. 46, 03028 Kyiv, Ukraine.

ORCID-Profile: Maria Szymonowicz, Agnieszka Rusak, Piotr Kuropka, Vitalii Boiko, Bartosz Mielan, Dariusz Hreniak, Maciej Dobrzyński

Förderung

  • Wroclaw Medical University (Wroclaw, Poland)

Zitieren

APA

Rygas, J., Szymonowicz, M., Rusak, A., Wawrzyńska, M., Kuropka, P., Boiko, V., Mielan, B., Hreniak, D., & Dobrzyński, M. (2025). Biocompatibility Evaluation of Surface-Modified Orthodontic Wires Using Graphene Layer. International Journal of Molecular Sciences. https://doi.org/10.3390/ijms26167804

Vancouver

Rygas J, Szymonowicz M, Rusak A, Wawrzyńska M, Kuropka P, Boiko V, et al. Biocompatibility Evaluation of Surface-Modified Orthodontic Wires Using Graphene Layer. International Journal of Molecular Sciences. 2025. doi:10.3390/ijms26167804

BibTeX
@article{Rygas2025,
  author = {Rygas, Joanna and Szymonowicz, Maria and Rusak, Agnieszka and Wawrzyńska, Magdalena and Kuropka, Piotr and Boiko, Vitalii and Mielan, Bartosz and Hreniak, Dariusz and Dobrzyński, Maciej},
  title = {Biocompatibility Evaluation of Surface-Modified Orthodontic Wires Using Graphene Layer},
  journal = {International Journal of Molecular Sciences},
  year = {2025},
  doi = {10.3390/ijms26167804}
}
Kostenlos starten →