EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Copper Sulfide Nanorod-Embedded Urinary Catheter with Hydrophobicity and Photothermal Sterilization

Muhammad Saukani iD, Chien-Hung Lai iD, Chinmaya Mutalik iD, Dyah Ika Krisnawati iD, Hsiu-Yi Chu, Tsung-Rong Kuo iD

International Journal of Molecular Sciences · 2024

DOI: 10.3390/ijms252111440 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Molecular Sciences, 2024. Verfasst von Muhammad Saukani und 5 weiteren Autor:innen. Beteiligte Einrichtung: International Ph.D. Program in Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan. Hauptthemen laut MEDLINE: Copper, Nanotubes, Hydrophobic and Hydrophilic Interactions, Anti-Bacterial Agents. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Council, Taiwan, Taipei Medical University Hospital, Taipei Medical University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The high prevalence of catheter-associated urinary tract infections (CAUTIs) is causing significant concern in healthcare systems. Antibacterial urinary catheters have been developed to prevent CAUTIs in clinical application. In this work, a copper sulfide nanorod (CuS NR)-embedded urinary catheter (CuS/UC) was designed as an antibacterial urinary catheter with photothermal sterilization. The CuS NRs with low cytotoxicity were synthesized via the hydrothermal method. The CuS NRs were embedded into urinary catheters at different weight percentages. The CuS/UC exhibited homogenous surface roughness, low wettability, hydrophobicity, and low adhesiveness, promoting minimal interaction with bacteria and healthy cells. Under near-infrared (NIR) laser irradiation, the 0.8 weight percentage of CuS NRs in the urinary catheter (0.8CuS/UC) reached a temperature of 67.4 °C, demonstrating its photothermal antibacterial activity and suitability for catheter sterilization. Agar plate test verified that CuS/UCs exhibited a superior photothermal antibacterial activity against both Gram-negative Escherichia coli (E. coli) and Gram-positive Streptococcus aureus (S. aureus). Moreover, the 0.8CuS/UC exhibited excellent biocompatibility and anti-cell adhesion properties. The 0.8CuS/UC with photothermal performance, excellent biocompatibility, and anti-cell adhesion properties demonstrated its potential as a photothermal antibacterial catheter for clinical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CopperNanotubesHydrophobic and Hydrophilic InteractionsAnti-Bacterial AgentsUrinary CathetersEscherichia coliSulfidesHumansStaphylococcus aureusSterilizationMicrobial Sensitivity TestsAnimalsMice

Stichwörter der Autor:innen

anti-cell adhesionbiocompatibilitycopper sulfidehydrophobicityphotothermal therapyurinary catheter

Substanzen

CopperAnti-Bacterial AgentsSulfidescupric sulfide

Autor:innen und Institutionen

  • International Ph.D. Program in Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan.
  • Department of Mechanical Engineering, Faculty of Engineering, Universitas Islam Kalimantan MAB, Banjarmasin 70124, Kalimantan Selatan, Indonesia.
  • Department of Physical Medicine and Rehabilitation, School of Medicine, College of Medicine, Taipei Medical University, Taipei 11031, Taiwan.
  • Department of Physical Medicine and Rehabilitation, Taipei Medical University Hospital, Taipei 11031, Taiwan.
  • Taipei Neuroscience Institute, Taipei Medical University, Taipei 11031, Taiwan.
  • Graduate Institute of Nanomedicine and Medical Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan.

ORCID-Profile: Muhammad Saukani, Chien-Hung Lai, Chinmaya Mutalik, Dyah Ika Krisnawati, Tsung-Rong Kuo

Förderung

  • National Science and Technology Council, Taiwan
  • Taipei Medical University Hospital
  • Taipei Medical University

Zitieren

APA

Saukani, M., Lai, C. H., Mutalik, C., Krisnawati, D. I., Chu, H. Y., & Kuo, T. R. (2024). Copper Sulfide Nanorod-Embedded Urinary Catheter with Hydrophobicity and Photothermal Sterilization. International Journal of Molecular Sciences. https://doi.org/10.3390/ijms252111440

Vancouver

Saukani M, Lai CH, Mutalik C, Krisnawati DI, Chu HY, Kuo TR. Copper Sulfide Nanorod-Embedded Urinary Catheter with Hydrophobicity and Photothermal Sterilization. International Journal of Molecular Sciences. 2024. doi:10.3390/ijms252111440

BibTeX
@article{Saukani2024,
  author = {Saukani, Muhammad and Lai, Chien-Hung and Mutalik, Chinmaya and Krisnawati, Dyah Ika and Chu, Hsiu-Yi and Kuo, Tsung-Rong},
  title = {Copper Sulfide Nanorod-Embedded Urinary Catheter with Hydrophobicity and Photothermal Sterilization},
  journal = {International Journal of Molecular Sciences},
  year = {2024},
  doi = {10.3390/ijms252111440}
}
Kostenlos starten →