Comparison of RNA-Sequencing Methods for Degraded RNA
International Journal of Molecular Sciences · 2024
DOI: 10.3390/ijms25116143 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift International Journal of Molecular Sciences, 2024. Verfasst von Hiroki Ura und 1 weiteren Autor:innen. Beteiligte Einrichtung: Center for Clinical Genomics, Kanazawa Medical University Hospital, 1-1 Daigaku, Uchinada, Kahoku 920-0923, Japan. Hauptthemen laut MEDLINE: Sequence Analysis, RNA, RNA Stability. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, Tokumori Yasumoto Memorial Trust for Researchers on Tuberous Sclerosis Complex and related Rare Neurological Disease, Kanazawa Medical University.
Abstract (Originalsprache)
RNA sequencing (RNA-Seq) is a powerful technique and is increasingly being used in clinical research and drug development. Currently, several RNA-Seq methods have been developed. However, the relative advantage of each method for degraded RNA and low-input RNA, such as RNA samples collected in the field of clinical setting, has remained unknown. The Standard method of RNA-Seq captures mRNA by poly(A) capturing using Oligo dT beads, which is not suitable for degraded RNA. Here, we used three commercially available RNA-Seq library preparation kits (SMART-Seq, xGen Broad-range, and RamDA-Seq) using random primer instead of Oligo dT beads. To evaluate the performance of these methods, we compared the correlation, the number of detected expressing genes, and the expression levels with the Standard RNA-Seq method. Although the performance of RamDA-Seq was similar to that of Standard RNA-Seq, the performance for low-input RNA and degraded RNA has decreased. The performance of SMART-Seq was better than xGen and RamDA-Seq in low-input RNA and degraded RNA. Furthermore, the depletion of ribosomal RNA (rRNA) improved the performance of SMART-Seq and xGen due to increased expression levels. SMART-Seq with rRNA depletion has relative advantages for RNA-Seq using low-input and degraded RNA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Center for Clinical Genomics, Kanazawa Medical University Hospital, 1-1 Daigaku, Uchinada, Kahoku 920-0923, Japan.
- Division of Genomic Medicine, Department of Advanced Medicine, Medical Research Institute, Kanazawa Medical University, 1-1 Daigaku, Uchinada, Kahoku 920-0923, Japan.
ORCID-Profile: Hiroki Ura, Yo Niida
Förderung
- Japan Society for the Promotion of Science
- Tokumori Yasumoto Memorial Trust for Researchers on Tuberous Sclerosis Complex and related Rare Neurological Disease
- Kanazawa Medical University
Zitieren
APA
Ura, H., & Niida, Y. (2024). Comparison of RNA-Sequencing Methods for Degraded RNA. International Journal of Molecular Sciences. https://doi.org/10.3390/ijms25116143
Vancouver
Ura H, Niida Y. Comparison of RNA-Sequencing Methods for Degraded RNA. International Journal of Molecular Sciences. 2024. doi:10.3390/ijms25116143
BibTeX
@article{Ura2024,
author = {Ura, Hiroki and Niida, Yo},
title = {Comparison of RNA-Sequencing Methods for Degraded RNA},
journal = {International Journal of Molecular Sciences},
year = {2024},
doi = {10.3390/ijms25116143}
}
EUVIMED