Spinning Disk Confocal Microscopy for Optimized and Quantified Live Imaging of 3D Mitochondrial Network
International Journal of Molecular Sciences · 2024
DOI: 10.3390/ijms25094819 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Molecular Sciences, 2024. Verfasst von Somaieh Ahmadian und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Toxicogenomics, Maastricht University Medical Centre+, 6229 ER Maastricht, The Netherlands. Hauptthemen laut MEDLINE: Mitochondria, Microscopy, Confocal, Imaging, Three-Dimensional. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: GROW Research Institute for Oncology and Reproduction Maastricht university.
Abstract (Originalsprache)
Mitochondria are the energy factories of a cell, and depending on the metabolic requirements, the mitochondrial morphology, quantity, and membrane potential in a cell change. These changes are frequently assessed using commercially available probes. In this study, we tested the suitability of three commercially available probes—namely 5′,6,6′-tetrachloro-1,1′,3,3′-tetraethylbenzimidazolo-carbocyanine iodide (JC-1), MitoTracker Red CMX Rox (CMXRos), and tetramethylrhodamine methyl ester (TMRM)—for assessing the mitochondrial quantity, morphology, and membrane potential in living human mesoangioblasts in 3D with confocal laser scanning microscope (CLSM) and scanning disk confocal microscope (SDCM). Using CLSM, JC-1, and CMXRos—but not TMRM—uncovered considerable background and variation. Using SDCM, the background signal only remained apparent for the JC-1 monomer. Repetitive imaging of CMXRos and JC-1—but not TMRM—demonstrated a 1.5–2-fold variation in signal intensity between cells using CLSM. The use of SDCM drastically reduced this variation. The slope of the relative signal intensity upon repetitive imaging using CLSM was lowest for TMRM (−0.03) and highest for CMXRos (0.16). Upon repetitive imaging using SDCM, the slope varied from 0 (CMXRos) to a maximum of −0.27 (JC-1 C1). Conclusively, our data show that TMRM staining outperformed JC-1 and CMXRos dyes in a (repetitive) 3D analysis of the entire mitochondrial quantity, morphology, and membrane potential in living cells.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Toxicogenomics, Maastricht University Medical Centre+, 6229 ER Maastricht, The Netherlands.
- GROW Research Institute for Oncology and Reproduction, Maastricht University, 6229 ER Maastricht, The Netherlands.
- Department of Genetics and Molecular Cell Biology, Maastricht University, 6229 ER Maastricht, The Netherlands.
- Institutefor Mental Health and Neurosciences (MHeNS), Maastricht University Medical Centre+, 6229 ER Maastricht, The Netherlands.
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, 6229 ER Maastricht, The Netherlands.
- IMCAR, Institute for Molecular Cardiovascular Research, Universitätsklinikum Aachen, 52074 Aachen, Germany.
ORCID-Profile: Florence H J van Tienen
Förderung
- GROW Research Institute for Oncology and Reproduction Maastricht university
Zitieren
APA
Ahmadian, S., Lindsey, P. J., Smeets, H. J. M., van Tienen, F. H. J., & van Zandvoort, M. A. M. J. (2024). Spinning Disk Confocal Microscopy for Optimized and Quantified Live Imaging of 3D Mitochondrial Network. International Journal of Molecular Sciences. https://doi.org/10.3390/ijms25094819
Vancouver
Ahmadian S, Lindsey PJ, Smeets HJM, van Tienen FHJ, van Zandvoort MAMJ. Spinning Disk Confocal Microscopy for Optimized and Quantified Live Imaging of 3D Mitochondrial Network. International Journal of Molecular Sciences. 2024. doi:10.3390/ijms25094819
BibTeX
@article{Ahmadian2024,
author = {Ahmadian, Somaieh and Lindsey, Patrick J and Smeets, Hubert J M and van Tienen, Florence H J and van Zandvoort, Marc A M J},
title = {Spinning Disk Confocal Microscopy for Optimized and Quantified Live Imaging of 3D Mitochondrial Network},
journal = {International Journal of Molecular Sciences},
year = {2024},
doi = {10.3390/ijms25094819}
}
EUVIMED