EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development of an Innovative Biosensor Based on Graphene/PEDOT/Tyrosinase for the Detection of Phenolic Compounds in River Waters

Alexandra Virginia Bounegru iD, Catalina Iticescu iD, Lucian P Georgescu, Constantin Apetrei iD

International Journal of Molecular Sciences · 17.04.2024 · 25 (8) · 4419

DOI: 10.3390/ijms25084419 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Molecular Sciences, online erschienen am 17.04.2024. Verfasst von Alexandra Virginia Bounegru und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Physics and Environment, Faculty of Sciences and Environment, "Dunărea de Jos" University of Galati, 47 Domneasca Street, 80…. Hauptthemen laut MEDLINE: Biosensing Techniques, Graphite, Monophenol Monooxygenase, Rivers. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the project An Integrated System for the Complex Environmental Research and Monitoring in the Danube River Area, REXDAN, European Regional Development Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Phenolic compounds, originating from industrial, agricultural, and urban sources, can leach into flowing waters, adversely affecting aquatic life, biodiversity, and compromising the quality of drinking water, posing potential health hazards to humans. Thus, monitoring and mitigating the presence of phenolic compounds in flowing waters are essential for preserving ecosystem integrity and safeguarding public health. This study explores the development and performance of an innovative sensor based on screen-printed electrode (SPE) modified with graphene (GPH), poly(3,4-ethylenedioxythiophene) (PEDOT), and tyrosinase (Ty), designed for water analysis, focusing on the manufacturing process and the obtained electroanalytical results. The proposed biosensor (SPE/GPH/PEDOT/Ty) was designed to achieve a high level of precision and sensitivity, as well as to allow efficient analytical recoveries. Special attention was given to the manufacturing process and optimization of the modifying elements’ composition. This study highlights the potential of the biosensor as an efficient and reliable solution for water analysis. Modification with graphene, the synthesis and electropolymerization deposition of the PEDOT polymer, and tyrosinase immobilization contributed to obtaining a high-performance and robust biosensor, presenting promising perspectives in monitoring the quality of the aquatic environment. Regarding the electroanalytical experimental results, the detection limits (LODs) obtained with this biosensor are extremely low for all phenolic compounds (8.63 × 10−10 M for catechol, 7.72 × 10−10 M for 3-methoxycatechol, and 9.56 × 10−10 M for 4-methylcatechol), emphasizing its ability to accurately measure even subtle variations in the trace compound parameters. The enhanced sensitivity of the biosensor facilitates detection and quantification in river water samples. Analytical recovery is also an essential aspect, and the biosensor presents consistent and reproducible results. This feature significantly improves the reliability and usefulness of the biosensor in practical applications, making it suitable for monitoring industrial or river water.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesGraphiteMonophenol MonooxygenaseRiversPolymersPhenolsWater Pollutants, ChemicalBridged Bicyclo Compounds, HeterocyclicEnzymes, ImmobilizedElectrochemical TechniquesElectrodesLimit of Detection

Stichwörter der Autor:innen

biosensorcatecholselectivitysensitivitysquare wave voltammetry

Substanzen

GraphiteMonophenol MonooxygenasePolymersPhenolspoly(3,4-ethylene dioxythiophene)Water Pollutants, ChemicalBridged Bicyclo Compounds, HeterocyclicEnzymes, Immobilized

Autor:innen und Institutionen

  • Department of Chemistry, Physics and Environment, Faculty of Sciences and Environment, "Dunărea de Jos" University of Galati, 47 Domneasca Street, 800008 Galați, Romania.

ORCID-Profile: Alexandra Virginia Bounegru, Catalina Iticescu, Constantin Apetrei

Förderung

  • the project An Integrated System for the Complex Environmental Research and Monitoring in the Danube River Area, REXDAN
  • European Regional Development Fund

Zitieren

APA

Bounegru, A. V., Iticescu, C., Georgescu, L. P., & Apetrei, C. (2024). Development of an Innovative Biosensor Based on Graphene/PEDOT/Tyrosinase for the Detection of Phenolic Compounds in River Waters. International Journal of Molecular Sciences, 25(8), 4419. https://doi.org/10.3390/ijms25084419

Vancouver

Bounegru AV, Iticescu C, Georgescu LP, Apetrei C. Development of an Innovative Biosensor Based on Graphene/PEDOT/Tyrosinase for the Detection of Phenolic Compounds in River Waters. International Journal of Molecular Sciences. 2024;25(8):4419. doi:10.3390/ijms25084419

BibTeX
@article{Bounegru2024,
  author = {Bounegru, Alexandra Virginia and Iticescu, Catalina and Georgescu, Lucian P and Apetrei, Constantin},
  title = {Development of an Innovative Biosensor Based on Graphene/PEDOT/Tyrosinase for the Detection of Phenolic Compounds in River Waters},
  journal = {International Journal of Molecular Sciences},
  year = {2024},
  volume = {25},
  number = {8},
  pages = {4419},
  doi = {10.3390/ijms25084419}
}
Kostenlos starten →