Influence of Topography and Composition of Commercial Titanium Dental Implants on Cell Adhesion of Human Gingiva-Derived Mesenchymal Stem Cells: An In Vitro Study
International Journal of Molecular Sciences · 2023
DOI: 10.3390/ijms242316686 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Molecular Sciences, 2023. Verfasst von Vanessa Campos-Bijit und 6 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Nanobiomaterials, Research Institute of Dental Sciences, Faculty of Dentistry, Universidad de Chile, Santiago 8380544, Chile. Hauptthemen laut MEDLINE: Dental Implants. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 83 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Agencia Nacional de Investigación y Desarrollo, Chilean Governmental Agencia Nacional de Investigación y Desarrollo (ANID).
Abstract (Originalsprache)
The topography and composition of dental implant surfaces directly impact mesenchymal cell adhesion, proliferation, and differentiation, crucial aspects of achieving osseointegration. However, cell adhesion to biomaterials is considered a key step that drives cell proliferation and differentiation. The aim of this study was to characterize characterize the topography and composition of commercial titanium dental implants manufactured with different surface treatments (two sandblasted/acid-etched (SLA) (INNO Implants, Busan, Republic of Korea; BioHorizonsTM, Oceanside, CA, USA) and two calcium phosphate (CaP) treated (Biounite®, Berazategui, Argentina; Zimmer Biomet, Inc., Warsaw, IN, USA)) and to investigate their influence on the process of cell adhesion in vitro. A smooth surface implant (Zimmer Biomet, Inc.) was used as a control. For that, high-resolution methodologies such as scanning electron microscopy (SEM), X-ray dispersive spectroscopy (EDX), laser scanning confocal microscopy (LSCM), and atomic force microscopy (AFM) were employed. Protein adsorption and retromolar gingival mesenchymal stem cells (GMSCs) adhesion to the implant surfaces were evaluated after 48 h. The adherent cells were examined by SEM and LSCM for morphologic and quantitative analyses. ANOVA and Tukey tests (α = 0.05) were employed to determine statistical significance. SEM revealed that INNO, BioHorizonsTM, and Zimmer implants have an irregular surface, whereas Biounite® has a regular topography consisting of an ordered pattern. EDX confirmed a calcium and phosphate layer on the Biounite® and Zimmer surfaces, and AFM exhibited different roughness parameters. Protein adsorption and cell adhesion were detected on all the implant surfaces studied. However, the Biounite® implant with CaP and regular topography showed the highest protein adsorption capacity and density of adherent GMSCs. Although the Zimmer implant also had a CaP treatment, protein and cell adhesion levels were lower than those observed with Biounite®. Our findings indicated that the surface regularity of the implants is a more determinant factor in the cell adhesion process than the CaP treatment. A regular, nanostructured, hydrophilic, and moderately rough topography generates a higher protein adsorption capacity and thus promotes more efficient cell adhesion.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Laboratory of Nanobiomaterials, Research Institute of Dental Sciences, Faculty of Dentistry, Universidad de Chile, Santiago 8380544, Chile.
- Laboratory of Periodontal Biology, Faculty of Dentistry, Universidad de Chile, Santiago 8380492, Chile.
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Universidad de los Andes, Santiago 8150513, Chile.
- Department of Prosthesis, Faculty of Dentistry, Universidad de Chile, Santiago 8380544, Chile.
- Escuela de Tecnología Médica, Facultad de Ciencias, Pontificia Universidad Católica de Valparaíso, Valparaíso 2373223, Chile.
ORCID-Profile: Vanessa Campos-Bijit, Nicolás Cohn Inostroza, Cristian Cortez
Förderung
- Agencia Nacional de Investigación y Desarrollo
- Chilean Governmental Agencia Nacional de Investigación y Desarrollo (ANID)
Zitieren
APA
Campos-Bijit, V., Inostroza, N. C., Orellana, R., Rivera, A., Von Marttens, A., Cortez, C., & Covarrubias, C. (2023). Influence of Topography and Composition of Commercial Titanium Dental Implants on Cell Adhesion of Human Gingiva-Derived Mesenchymal Stem Cells: An In Vitro Study. International Journal of Molecular Sciences. https://doi.org/10.3390/ijms242316686
Vancouver
Campos-Bijit V, Inostroza NC, Orellana R, Rivera A, Von Marttens A, Cortez C, et al. Influence of Topography and Composition of Commercial Titanium Dental Implants on Cell Adhesion of Human Gingiva-Derived Mesenchymal Stem Cells: An In Vitro Study. International Journal of Molecular Sciences. 2023. doi:10.3390/ijms242316686
BibTeX
@article{CamposBijit2023,
author = {Campos-Bijit, Vanessa and Inostroza, Nicolás Cohn and Orellana, Rocío and Rivera, Alejandro and Von Marttens, Alfredo and Cortez, Cristian and Covarrubias, Cristian},
title = {Influence of Topography and Composition of Commercial Titanium Dental Implants on Cell Adhesion of Human Gingiva-Derived Mesenchymal Stem Cells: An In Vitro Study},
journal = {International Journal of Molecular Sciences},
year = {2023},
doi = {10.3390/ijms242316686}
}
EUVIMED