A Comprehensive Assessment of Tear-Film-Oriented Diagnosis (TFOD) in a Dacryoadenectomy Dry Eye Model
International Journal of Molecular Sciences · 2023
DOI: 10.3390/ijms242216510 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Molecular Sciences, 2023. Verfasst von Saki Sakakura und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan. Hauptthemen laut MEDLINE: Lacrimal Apparatus, Dry Eye Syndromes. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Kitayama Labes Co., Ltd.., Kitayama Labes Co., Ltd..
Abstract (Originalsprache)
Tear film instability is a major cause of dry eye disease. In order to treat patients with short tear film breakup time (TBUT)-type dry eye, the development of tear film stabilizing agents is essential. However, the lack of an appropriate animal model of tear film instability has made drug development difficult. Although rabbit dry eye models have been reported in the past, there are only a few reports that focus on tear film instability. Herein, we assessed the tear film stability of a rabbit dry eye model induced by dacryoadenectomy. A clinical evaluation of the ocular surface, interferometry, and histological assessments of the cornea and conjunctiva were performed. Following the removal of the lacrimal glands, TBUT was shortened significantly, with dimple and random breakup patterns prominently observed. Furthermore, the blink rate in this model increased after dacryoadenectomy, suggesting that this model partially captured the phenotypes of human short TBUT-type dry eye and may be useful as an animal model for investigating potential drug candidates.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
- Department of Physiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
- Japan Society for the Promotion of Science, 5-3-1 Kojimachi, Chiyoda-ku, Tokyo 102-0083, Japan.
- Kitayama Labes Co., Ltd., 3052-1 Arai, Ina City 396-0025, Japan.
- Cornea Center and Eye Bank, Tokyo Dental College Ichikawa General Hospital, 5-11-13 Sugano, Ichikawa 272-8513, Japan.
- Department of Preventive Medicine and Public Health, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
ORCID-Profile: Yuichiro Ochiai, Kazunari Higa, Hiroshi Toshida, Kazuno Negishi, Shigeto Shimmura
Förderung
- Kitayama Labes Co., Ltd..
- Kitayama Labes Co., Ltd.
Zitieren
APA
Sakakura, S., Inagaki, E., Ochiai, Y., Yamamoto, M., Takai, N., Nagata, T., Higa, K., Sato, Y., Toshida, H., Murat, D., Hirayama, M., Ogawa, Y., Negishi, K., & Shimmura, S. (2023). A Comprehensive Assessment of Tear-Film-Oriented Diagnosis (TFOD) in a Dacryoadenectomy Dry Eye Model. International Journal of Molecular Sciences. https://doi.org/10.3390/ijms242216510
Vancouver
Sakakura S, Inagaki E, Ochiai Y, Yamamoto M, Takai N, Nagata T, et al. A Comprehensive Assessment of Tear-Film-Oriented Diagnosis (TFOD) in a Dacryoadenectomy Dry Eye Model. International Journal of Molecular Sciences. 2023. doi:10.3390/ijms242216510
BibTeX
@article{Sakakura2023,
author = {Sakakura, Saki and Inagaki, Emi and Ochiai, Yuichiro and Yamamoto, Masatoshi and Takai, Naofumi and Nagata, Taeko and Higa, Kazunari and Sato, Yasunori and Toshida, Hiroshi and Murat, Dogru and Hirayama, Masatoshi and Ogawa, Yoko and Negishi, Kazuno and Shimmura, Shigeto},
title = {A Comprehensive Assessment of Tear-Film-Oriented Diagnosis (TFOD) in a Dacryoadenectomy Dry Eye Model},
journal = {International Journal of Molecular Sciences},
year = {2023},
doi = {10.3390/ijms242216510}
}
EUVIMED