Fachartikel in der Zeitschrift International Journal of Environmental Research and Public Health, 2026. Verfasst von Federica Marino und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biological, Geological, and Environmental Sciences, University of Bologna, 40126 Bologna, Italy. Hauptthemen laut MEDLINE: Nucleic Acid Amplification Techniques, Cross Infection, Staphylococcus aureus, Enterococcus. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Class S.r.l..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hospital environments are recognized as significant reservoirs of nosocomial pathogens, contributing to the onset of healthcare-associated infections (HAIs). Timely microbiological monitoring is essential to mitigate infection risks. However, gold-standard methods based on culture and biochemical techniques are time-consuming and may underestimate microbial contamination, potentially delaying interventions. This study proposes a novel approach for surface monitoring using loop-mediated isothermal amplification (LAMP) for the rapid detection of key nosocomial pathogens, such as Pseudomonas aeruginosa, Staphylococcus aureus, and Enterococcus spp. A total of 145 surface samples were collected from six Italian hospitals and analyzed by both standard culture and LAMP methods, following two different incubation times (6 and 9 h) using pre-enrichment medium. Comparison with the reference method revealed that the LAMP assay achieved a sensitivity of 1.00 for all target pathogens at both 6 and 9 h of incubation. Specificity values were slightly higher at 6 h compared to 9 h: 0.93 vs 0.90 for P. aeruginosa, 0.91 vs 0.89 for Enterococcus spp., while remaining 0.92 for S. aureus, at both incubation times. These results suggest that a 6-h incubation period offers an optimal balance between speed and diagnostic accuracy, making LAMP a promising tool for rapid microbiological surveillance in healthcare settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nucleic Acid Amplification TechniquesCross InfectionStaphylococcus aureusEnterococcusPseudomonas aeruginosaMolecular Diagnostic TechniquesHumansHospitalsSensitivity and SpecificityItaly

Stichwörter der Autor:innen

LAMPhealthcare-associated infectionshospital surfacesmicrobiological monitoringnosocomial pathogensrapid detection

Autor:innen und Institutionen

  • Department of Biological, Geological, and Environmental Sciences, University of Bologna, 40126 Bologna, Italy.

ORCID-Profile: Federica Marino, Caterina Bonincontro, Laura Caligaris, Derelitto Carlo, Luna Girolamini, Sandra Cristino

Förderung

  • Class S.r.l.

Zitieren

APA

Marino, F., Bonincontro, C., Caligaris, L., Carlo, D., Girolamini, L., & Cristino, S. (2026). Improving Microbiological Monitoring of Hospital Surfaces: Loop-Mediated Isothermal Amplification (LAMP) as a New Approach for Rapid Nosocomial Pathogens Detection. International Journal of Environmental Research and Public Health. https://doi.org/10.3390/ijerph23020174

Vancouver

Marino F, Bonincontro C, Caligaris L, Carlo D, Girolamini L, Cristino S. Improving Microbiological Monitoring of Hospital Surfaces: Loop-Mediated Isothermal Amplification (LAMP) as a New Approach for Rapid Nosocomial Pathogens Detection. International Journal of Environmental Research and Public Health. 2026. doi:10.3390/ijerph23020174

BibTeX
@article{Marino2026,
  author = {Marino, Federica and Bonincontro, Caterina and Caligaris, Laura and Carlo, Derelitto and Girolamini, Luna and Cristino, Sandra},
  title = {Improving Microbiological Monitoring of Hospital Surfaces: Loop-Mediated Isothermal Amplification (LAMP) as a New Approach for Rapid Nosocomial Pathogens Detection},
  journal = {International Journal of Environmental Research and Public Health},
  year = {2026},
  doi = {10.3390/ijerph23020174}
}
Kostenlos starten →