EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Correlation between MOVA3D, a Monocular Movement Analysis System, and Qualisys Track Manager (QTM) during Lower Limb Movements in Healthy Adults: A Preliminary Study

Liliane Pinho de Almeida, Leandro Caetano Guenka, Danielle de Oliveira Felipe, Renato Porfirio Ishii, Pedro Senna de Campos, Thomaz Nogueira Burke iD

International Journal of Environmental Research and Public Health · 2023

DOI: 10.3390/ijerph20176657 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Environmental Research and Public Health, 2023. Verfasst von Liliane Pinho de Almeida und 5 weiteren Autor:innen. Beteiligte Einrichtung: Allied Health Institute, Federal University of Mato Grosso do Sul, Campo Grande 79070-900, Brazil. Hauptthemen laut MEDLINE: Movement, Augmented Reality. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior—Brasil (CAPES).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

New technologies based on virtual reality and augmented reality offer promising perspectives in an attempt to increase the assessment of human kinematics. The aim of this work was to develop a markerless 3D motion analysis capture system (MOVA3D) and to test it versus Qualisys Track Manager (QTM). A digital camera was used to capture the data, and proprietary software capable of automatically inferring the joint centers in 3D and performing the angular kinematic calculations of interest was developed for such analysis. In the experiment, 10 subjects (22 to 50 years old), 5 men and 5 women, with a body mass index between 18.5 and 29.9 kg/m2, performed squatting, hip flexion, and abduction movements, and both systems measured the hip abduction/adduction angle and hip flexion/extension, simultaneously. The mean value of the difference between the QTM system and the MOVA3D system for all frames for each joint angle was analyzed with Pearson’s correlation coefficient (r). The MOVA3D system reached good (above 0.75) or excellent (above 0.90) correlations in 6 out of 8 variables. The average error remained below 12° in only 20 out of 24 variables analyzed. The MOVA3D system is therefore promising for use in telerehabilitation or other applications where this level of error is acceptable. Future studies should continue to validate the MOVA3D as updated versions of their software are developed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MovementAugmented RealityMaleHumansAdultFemaleYoung AdultMiddle AgedPostureMotionLower Extremity

Stichwörter der Autor:innen

capture systemmotion analysistelerehabilitation

Autor:innen und Institutionen

  • Allied Health Institute, Federal University of Mato Grosso do Sul, Campo Grande 79070-900, Brazil.
  • Medicine, State University of Mato Grosso do Sul, Campo Grande 79115-898, Brazil.

ORCID-Profile: Thomaz Nogueira Burke

Förderung

  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior—Brasil (CAPES)

Zitieren

APA

Almeida, L. P., Guenka, L. C., Felipe, D. O., Ishii, R. P., Campos, P. S., & Burke, T. N. (2023). Correlation between MOVA3D, a Monocular Movement Analysis System, and Qualisys Track Manager (QTM) during Lower Limb Movements in Healthy Adults: A Preliminary Study. International Journal of Environmental Research and Public Health. https://doi.org/10.3390/ijerph20176657

Vancouver

Almeida LP, Guenka LC, Felipe DO, Ishii RP, Campos PS, Burke TN. Correlation between MOVA3D, a Monocular Movement Analysis System, and Qualisys Track Manager (QTM) during Lower Limb Movements in Healthy Adults: A Preliminary Study. International Journal of Environmental Research and Public Health. 2023. doi:10.3390/ijerph20176657

BibTeX
@article{Almeida2023,
  author = {Almeida, Liliane Pinho de and Guenka, Leandro Caetano and Felipe, Danielle de Oliveira and Ishii, Renato Porfirio and Campos, Pedro Senna de and Burke, Thomaz Nogueira},
  title = {Correlation between MOVA3D, a Monocular Movement Analysis System, and Qualisys Track Manager (QTM) during Lower Limb Movements in Healthy Adults: A Preliminary Study},
  journal = {International Journal of Environmental Research and Public Health},
  year = {2023},
  doi = {10.3390/ijerph20176657}
}
Kostenlos starten →