EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Reliability of ADR Jumping Photocell: Comparison of Beam Cut at Forefoot and Midfoot

Jose M Jimenez-Olmedo iD, Alfonso Penichet-Tomas iD, Basilio Pueo iD, Lamberto Villalon-Gasch iD

International Journal of Environmental Research and Public Health · 2023

DOI: 10.3390/ijerph20115935 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Environmental Research and Public Health, 2023. Verfasst von Jose M Jimenez-Olmedo und 3 weiteren Autor:innen. Beteiligte Einrichtung: Research Group in Health, Physical Activity, and Sports Technology (Health-Tech), Faculty of Education, University of Alicante, 03690 San Vicente del…. Hauptthemen laut MEDLINE: Volleyball. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Generalitat Valenciana.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The ability to detect small changes in a vertical jump is crucial when data are used by sports science specialists to monitor their athletes. This study aimed to analyze the intrasession reliability of the ADR jumping photocell and the reliability relative to the position of the transmitter when it is located facing the phalanges of the foot (forefoot) or the metatarsal area (midfoot). A total of 12 female volleyball players performed 240 countermovement jumps (CMJ), alternating both methods. The intersession reliability was higher for the forefoot method (ICC = 0.96; CCC = 0.95; SEM = 1.15 cm; CV = 4.11%) than for the midfoot method (ICC = 0.85; CCC = 0.81; SEM = 3.68 cm; CV = 8.75%). Similarly, the sensitivity values were better for the forefoot method (SWC = 0.32) than for the midfoot method (SWC = 1.04). Significant differences were found between the methods (13.5 cm, p < 0.05, ES = 2.1) with low agreement (rs = 0.57; ICC = 0.49; CCC = 0.15; SEM = 4.7 cm) and heteroscedasticity was observed (r2 > 0.1). In conclusion, the ADR jumping photocell is shown to be a reliable tool for measuring CMJs. However, the reliability of the instrument can be influenced depending on the placement of the device. Comparing the two methods, the midfoot placement was less reliable as indicated by higher values of SEM and systematic error, and thus its use is not recommended.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

VolleyballHumansFemaleReproducibility of ResultsAthletesHandFoot

Stichwörter der Autor:innen

accuracybetween-methodsconsistencycountermovement jumperrorsensibility

Autor:innen und Institutionen

  • Research Group in Health, Physical Activity, and Sports Technology (Health-Tech), Faculty of Education, University of Alicante, 03690 San Vicente del Raspeig, Spain.

ORCID-Profile: Jose M Jimenez-Olmedo, Alfonso Penichet-Tomas, Basilio Pueo, Lamberto Villalon-Gasch

Förderung

  • Generalitat Valenciana

Zitieren

APA

Jimenez-Olmedo, J. M., Penichet-Tomas, A., Pueo, B., & Villalon-Gasch, L. (2023). Reliability of ADR Jumping Photocell: Comparison of Beam Cut at Forefoot and Midfoot. International Journal of Environmental Research and Public Health. https://doi.org/10.3390/ijerph20115935

Vancouver

Jimenez-Olmedo JM, Penichet-Tomas A, Pueo B, Villalon-Gasch L. Reliability of ADR Jumping Photocell: Comparison of Beam Cut at Forefoot and Midfoot. International Journal of Environmental Research and Public Health. 2023. doi:10.3390/ijerph20115935

BibTeX
@article{JimenezOlmedo2023,
  author = {Jimenez-Olmedo, Jose M and Penichet-Tomas, Alfonso and Pueo, Basilio and Villalon-Gasch, Lamberto},
  title = {Reliability of ADR Jumping Photocell: Comparison of Beam Cut at Forefoot and Midfoot},
  journal = {International Journal of Environmental Research and Public Health},
  year = {2023},
  doi = {10.3390/ijerph20115935}
}
Kostenlos starten →