EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of Long-Term Flow Controller for Monitoring Gases and Vapors in Buildings Impacted by Vapor Intrusion

Alan Rossner, David P Wick iD, Christopher Lutes iD, Benjamin Stone, Michelle Crimi

International Journal of Environmental Research and Public Health · 2023

DOI: 10.3390/ijerph20064811 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Environmental Research and Public Health, 2023. Verfasst von Alan Rossner und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Sustainable Environment, Clarkson University, Potsdam, NY 13699, USA. Hauptthemen laut MEDLINE: Trichloroethylene, Air Pollution, Indoor, Air Pollutants. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Environmental Security Technology Certification Program (ESTCP).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluated the use of a long-term capillary flow controller paired with an evacuated canister for indoor air exposure monitoring in a vapor intrusion (VI) environment with trichloroethylene in comparison to the traditional method utilizing a diaphragm flow controller. Traditionally, air sampling with 6 L evacuated canisters equipped with diaphragm flow controllers has been best suited for 8 to 24 h samples. New advances in capillary flow controllers can extend sampling to up to 3 weeks by reducing flow rates to 0.1 milliliters min−1. During six 2 wk sampling events, conventional diaphragm flow controller canisters were used to collect 24 h samples simultaneously with capillary flow controllers collecting 2 wk samples. Testing was performed at four indoor locations in buildings impacted by VI with co-located samples for each method at each location. All samples were analyzed using GC/MS, and the results were statistically analyzed to produce a direct comparison of the two sampling systems. Ninety-two percent of the 14 d capillary samples were within the 95% levels of agreement of the average concentration of the diaphragm flow controllers. The ability to collect 14 days of data, with less occupant disturbance, allows for improved exposure assessments and thus improved risk management decisions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TrichloroethyleneAir Pollution, IndoorAir PollutantsEnvironmental MonitoringGases

Stichwörter der Autor:innen

Summa canistercapillary flow controllerdiaphragm flow controllertime-integrated samplingvolatile organic compounds

Substanzen

GasesTrichloroethyleneAir Pollutants

Autor:innen und Institutionen

  • Institute for Sustainable Environment, Clarkson University, Potsdam, NY 13699, USA.
  • School of Individualized Study, Rochester Institute of Technology, Rochester, NY 14623, USA.
  • Jacobs Engineering Group Inc., Dallas, TX 75201, USA.

ORCID-Profile: David P Wick, Christopher Lutes

Förderung

  • Environmental Security Technology Certification Program (ESTCP)

Zitieren

APA

Rossner, A., Wick, D. P., Lutes, C., Stone, B., & Crimi, M. (2023). Evaluation of Long-Term Flow Controller for Monitoring Gases and Vapors in Buildings Impacted by Vapor Intrusion. International Journal of Environmental Research and Public Health. https://doi.org/10.3390/ijerph20064811

Vancouver

Rossner A, Wick DP, Lutes C, Stone B, Crimi M. Evaluation of Long-Term Flow Controller for Monitoring Gases and Vapors in Buildings Impacted by Vapor Intrusion. International Journal of Environmental Research and Public Health. 2023. doi:10.3390/ijerph20064811

BibTeX
@article{Rossner2023,
  author = {Rossner, Alan and Wick, David P and Lutes, Christopher and Stone, Benjamin and Crimi, Michelle},
  title = {Evaluation of Long-Term Flow Controller for Monitoring Gases and Vapors in Buildings Impacted by Vapor Intrusion},
  journal = {International Journal of Environmental Research and Public Health},
  year = {2023},
  doi = {10.3390/ijerph20064811}
}
Kostenlos starten →