Implementation of an Environmental Cleaning Protocol in Hospital Critical Areas Using a UV-C Disinfection Robot
International Journal of Environmental Research and Public Health · 28.02.2023 · 20 (5) · 4284
DOI: 10.3390/ijerph20054284 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift International Journal of Environmental Research and Public Health, online erschienen am 28.02.2023. Verfasst von Beatrice Casini und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy. Hauptthemen laut MEDLINE: Robotics, Cross Infection. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Improving the cleaning and disinfection of high-touch surfaces is one of the core components of reducing healthcare-associated infections. The effectiveness of an enhanced protocol applying UV-C irradiation for terminal room disinfection between two successive patients was evaluated. Twenty high-touch surfaces in different critical areas were sampled according to ISO 14698-1, both immediately pre- and post-cleaning and disinfection standard operating protocol (SOP) and after UV-C disinfection (160 sampling sites in each condition, 480 in total). Dosimeters were applied at the sites to assess the dose emitted. A total of 64.3% (103/160) of the sampling sites tested after SOP were positive, whereas only 17.5% (28/160) were positive after UV-C. According to the national hygienic standards for health-care setting, 9.3% (15/160) resulted in being non-compliant after SOP and only 1.2% (2/160) were non-compliant after UV-C disinfection. Operation theaters was the setting that resulted in being less compliant with the standard limit (≤15 colony-forming unit/24 cm2) after SOP (12%, 14/120 sampling sites) and where the UV-C treatment showed the highest effectiveness (1.6%, 2/120). The addition of UV-C disinfection to the standard cleaning and disinfection procedure had effective results in reducing hygiene failures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy.
- Hospital Management, University Hospital of Pisa, 56126 Pisa, Italy.
ORCID-Profile: Beatrice Casini, Benedetta Tuvo
Zitieren
APA
Casini, B., Tuvo, B., Scarpaci, M., Totaro, M., Badalucco, F., Briani, S., Luchini, G., Costa, A. L., & Baggiani, A. (2023). Implementation of an Environmental Cleaning Protocol in Hospital Critical Areas Using a UV-C Disinfection Robot. International Journal of Environmental Research and Public Health, 20(5), 4284. https://doi.org/10.3390/ijerph20054284
Vancouver
Casini B, Tuvo B, Scarpaci M, Totaro M, Badalucco F, Briani S, et al. Implementation of an Environmental Cleaning Protocol in Hospital Critical Areas Using a UV-C Disinfection Robot. International Journal of Environmental Research and Public Health. 2023;20(5):4284. doi:10.3390/ijerph20054284
BibTeX
@article{Casini2023,
author = {Casini, Beatrice and Tuvo, Benedetta and Scarpaci, Michela and Totaro, Michele and Badalucco, Federica and Briani, Silvia and Luchini, Grazia and Costa, Anna Laura and Baggiani, Angelo},
title = {Implementation of an Environmental Cleaning Protocol in Hospital Critical Areas Using a UV-C Disinfection Robot},
journal = {International Journal of Environmental Research and Public Health},
year = {2023},
volume = {20},
number = {5},
pages = {4284},
doi = {10.3390/ijerph20054284}
}
EUVIMED