EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessment of Dust, Chemical, Microbiological Pollutions and Microclimatic Parameters of Indoor Air in Sports Facilities

Justyna Szulc iD, Robert Cichowicz iD, Michał Gutarowski, Małgorzata Okrasa iD, Beata Gutarowska iD

International Journal of Environmental Research and Public Health · 2023

DOI: 10.3390/ijerph20021551 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Environmental Research and Public Health, 2023. Verfasst von Justyna Szulc und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Environmental Biotechnology, Faculty of Biotechnology and Food Science, Lodz University of Technology, Wólczańska 171/173, 90-530 Łódź,…. Hauptthemen laut MEDLINE: Air Pollution, Indoor, Basketball, Air Pollutants. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 77 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Provincial Fund for Environmental Protection and Water Management in Łódź.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aim of this study was to analyse the quality of indoor air in sport facilities in one of the sport centres in Poland with respect to microclimatic parameters (temperature, humidity, and air flow velocity), particulate matter concentrations (PM10, PM4, PM2.5, and PM1), gas concentrations (oxygen, ozone, hydrogen sulphide, sulphur dioxide, volatile organic compounds, and benzopyrene), and microbial contamination (the total number of bacteria, specifically staphylococci, including Staphylococcus aureus, haemolytic bacteria, Enterobacteriaceae, Pseudomonas fluorescens, actinomycetes, and the total number of fungi and xerophilic fungi). Measurements were made three times in May 2022 at 28 sampling points in 5 different sporting areas (the climbing wall, swimming pool, swimming pool changing room, and basketball and badminton courts) depending on the time of day (morning or afternoon) and on the outside building. The obtained results were compared with the standards for air quality in sports facilities. The air temperature (21–31 °C) was at the upper limit of thermal comfort, while the air humidity (RH < 40%) in the sports halls in most of the locations was below demanded values. The values for dust pollution in all rooms, except the swimming pool, exceeded the permissible limits, especially in the afternoons. Climatic conditions correlated with a high concentration of dust in the indoor air. Particulate matter concentrations of all fractions exceeded the WHO guidelines in all researched premises; the largest exceedances of standards occurred for PM2.5 (five-fold) and for PM10 (two-fold). There were no exceedances of gaseous pollutant concentrations in the air, except for benzopyrene, which resulted from the influence of the outside air. The total number of bacteria (5.1 × 101–2.0 × 104 CFU m−3) and fungi (3.0 × 101–3.75 × 102 CFU m−3) was exceeded in the changing room and the climbing wall hall. An increased number of staphylococci in the afternoon was associated with a large number of people training. The increased concentration of xerophilic fungi in the air correlated with the high dust content and low air humidity. Along with the increase in the number of users in the afternoon and their activities, the concentration of dust (several times) and microorganisms (1–2 log) in the air increased by several times and 1–2 log, respectively. The present study indicates which air quality parameters should be monitored and provides guidelines on how to increase the comfort of those who practice sports and work in sports facilities.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Air Pollution, IndoorBasketballAir PollutantsHumansDustParticulate MatterSulfur DioxideBenzopyrenesEnvironmental Monitoring

Stichwörter der Autor:innen

air qualitybioaerosolbiodiversitychemical contaminationmicroclimatic parametersparticulate mattersports facilities

Substanzen

DustParticulate MatterSulfur DioxideBenzopyrenesAir Pollutants

Autor:innen und Institutionen

  • Department of Environmental Biotechnology, Faculty of Biotechnology and Food Science, Lodz University of Technology, Wólczańska 171/173, 90-530 Łódź, Poland.
  • Institute of Environmental Engineering and Building Installations, Faculty of Civil Engineering, Architecture and Environmental Engineering, Lodz University of Technology, Al. Politechniki 6, 90-924 Łódź, Poland.
  • Department of Personal Protective Equipment, Central Institute for Labour Protection-National Research Institute, 90-133 Łódź, Poland.

ORCID-Profile: Justyna Szulc, Robert Cichowicz, Małgorzata Okrasa, Beata Gutarowska

Förderung

  • Provincial Fund for Environmental Protection and Water Management in Łódź

Zitieren

APA

Szulc, J., Cichowicz, R., Gutarowski, M., Okrasa, M., & Gutarowska, B. (2023). Assessment of Dust, Chemical, Microbiological Pollutions and Microclimatic Parameters of Indoor Air in Sports Facilities. International Journal of Environmental Research and Public Health. https://doi.org/10.3390/ijerph20021551

Vancouver

Szulc J, Cichowicz R, Gutarowski M, Okrasa M, Gutarowska B. Assessment of Dust, Chemical, Microbiological Pollutions and Microclimatic Parameters of Indoor Air in Sports Facilities. International Journal of Environmental Research and Public Health. 2023. doi:10.3390/ijerph20021551

BibTeX
@article{Szulc2023,
  author = {Szulc, Justyna and Cichowicz, Robert and Gutarowski, Michał and Okrasa, Małgorzata and Gutarowska, Beata},
  title = {Assessment of Dust, Chemical, Microbiological Pollutions and Microclimatic Parameters of Indoor Air in Sports Facilities},
  journal = {International Journal of Environmental Research and Public Health},
  year = {2023},
  doi = {10.3390/ijerph20021551}
}
Kostenlos starten →