EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Validity of a Novel Head-Mounted Display Augmented Reality Device with a Body-Worn Accelerometer (HMD-WRIT) and Dynamic Executive Function Assessment Against Standardized Tests in Healthy Older Versus Young Adults

James K. Buskirk

International Journal of Cognitive Sciences · 2026

DOI: 10.3390/ijcs2040020 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Cognitive Sciences, 2026. Verfasst von James K. Buskirk. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Neurologic pathologic conditions, including traumatic brain injury (TBI), and natural aging often present with concurrent physical and cognitive challenges. While functional physical capabilities may be accurately and reliably assessed, traditional cognitive measures rely on static testing methods that fail to incorporate functional movements.

Objective

These two studies aimed to validate a novel portable version of the previously validated laboratory-based Walking Response and Inhibition Test (WRIT), utilizing a head-mounted device (HMD) and a body-worn position sensor for dynamic measure of Executive Function (EF) during functional mobility.

Methods

Two observational studies were conducted across cohorts of healthy older and younger adults. To validate the portable device (HMD-WRIT), participant performance was benchmarked against two 3D Motion Analysis Systems. Additionally, a healthy elderly cohort study compared three standardized cognitive tests, while both studies utilized a functional mobility test.

Results

Data from both observational studies demonstrated that the portable HMD-WRIT accurately captured postural responses to visual commands during walking. Performance metrics successfully correlated with motion-capture data and established static cognitive benchmarks.

Conclusions

The HMD-WRIT is a viable, portable option for measuring EF during functional movement. This system bridges the gap between static cognitive testing and real-world mobility assessments in both young and aging populations.

Zitieren

APA

Buskirk, J. K. (2026). Validity of a Novel Head-Mounted Display Augmented Reality Device with a Body-Worn Accelerometer (HMD-WRIT) and Dynamic Executive Function Assessment Against Standardized Tests in Healthy Older Versus Young Adults. International Journal of Cognitive Sciences. https://doi.org/10.3390/ijcs2040020

Vancouver

Buskirk JK. Validity of a Novel Head-Mounted Display Augmented Reality Device with a Body-Worn Accelerometer (HMD-WRIT) and Dynamic Executive Function Assessment Against Standardized Tests in Healthy Older Versus Young Adults. International Journal of Cognitive Sciences. 2026. doi:10.3390/ijcs2040020

BibTeX
@article{Buskirk2026,
  author = {Buskirk, James K.},
  title = {Validity of a Novel Head-Mounted Display Augmented Reality Device with a Body-Worn Accelerometer (HMD-WRIT) and Dynamic Executive Function Assessment Against Standardized Tests in Healthy Older Versus Young Adults},
  journal = {International Journal of Cognitive Sciences},
  year = {2026},
  doi = {10.3390/ijcs2040020}
}
Kostenlos starten →