EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Matrix-Dependent Sensitivity of Two Pan-Trematode PCR Assays for Detecting Schistosoma spp. in Clinical Human Samples

Hagen Frickmann iD, Andreas Hahn iD, Kirsten Alexandra Eberhardt iD, Ulrike Loderstädt, Norbert Georg Schwarz, Ralf Matthias Hagen iD

Infectious Disease Reports · 27.03.2026 · 18 (2) · 27

DOI: 10.3390/idr18020027 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Infectious Disease Reports, online erschienen am 27.03.2026. Verfasst von Hagen Frickmann und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Microbiology and Hospital Hygiene, Bundeswehr Hospital Hamburg, 22049 Hamburg, Germany. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Schistosoma spp. are trematodes occurring in tropical endemic areas but can be imported to non-endemic regions as causes of travel-associated infections. In this study, two pan-trematode-specific real-time PCR assays were evaluated for their diagnostic sensitivity in detecting Schistosoma spp. DNA in diagnostic human samples.

Methods

Two previously described pan-trematode-specific real-time PCR assays were comparatively assessed using diagnostic samples containing DNA of either the S. haematobium complex or the S. mansoni complex, as confirmed by Schistosoma species complex-specific real-time PCR.

Results

Out of a total of 655 samples containing Schistosoma spp. DNA, positive signals in at least one of the two pan-trematode real-time PCR assays were recorded for 17 (2.6%) nucleic acid extractions. Although sensitivity was in the >90% range for stool samples, only a few individual blood plasma and serum samples, and none of the Schistosoma spp. DNA-containing tissue or urine samples, tested positive by pan-trematode PCR. The lower sensitivity of pan-trematode PCR compared with Schistosoma spp.-specific PCR was semi-quantitatively confirmed by higher cycle threshold (Ct) values in the former. When comparing samples with concordant versus discordant positive results for Schistosoma spp.-specific and pan-trematode PCR, Ct values of the Schistosoma spp.-specific PCR were lower in concordantly positive samples than in discordantly positive samples.

Conclusions

While the assessed pan-trematode PCR assays showed insufficient sensitivity as screening tools for blood plasma, blood serum, tissue, and urine samples from individuals with suspected schistosomiasis, they were sufficiently sensitive when applied to stool samples, in which substantial amounts of target DNA, as indicated by low Ct values in the Schistosoma species complex-specific real-time PCR assays, can be expected. For screening for Schistosoma spp. DNA in sample materials other than stool, the use of highly sensitive target-specific PCR remains necessary.

Schlagwörter

Stichwörter der Autor:innen

Schistosoma haematobium complexSchistosoma mansoni complexdiagnostic accuracypan-trematode PCRschistosomiasistest comparison

Autor:innen und Institutionen

  • Department of Microbiology and Hospital Hygiene, Bundeswehr Hospital Hamburg, 22049 Hamburg, Germany.
  • Institute for Medical Microbiology, Virology and Hygiene, University Medicine Rostock, 18057 Rostock, Germany.
  • Department of Gastroenterology, Hepatology and Infectious Diseases, University Hospital and Medical Faculty of the Heinrich Heine University, 40225 Düsseldorf, Germany.
  • Department of Tropical Medicine, Bernhard Nocht Institute for Tropical Medicine, 20359 Hamburg, Germany.
  • Institute of Infection Control and Infectious Diseases, University Medical Center Göttingen, 37075 Göttingen, Germany.
  • Independent Researcher, 67459 Böhl-Iggelheim, Germany.

ORCID-Profile: Hagen Frickmann, Andreas Hahn, Kirsten Alexandra Eberhardt, Ralf Matthias Hagen

Zitieren

APA

Frickmann, H., Hahn, A., Eberhardt, K. A., Loderstädt, U., Schwarz, N. G., & Hagen, R. M. (2026). Matrix-Dependent Sensitivity of Two Pan-Trematode PCR Assays for Detecting Schistosoma spp. in Clinical Human Samples. Infectious Disease Reports, 18(2), 27. https://doi.org/10.3390/idr18020027

Vancouver

Frickmann H, Hahn A, Eberhardt KA, Loderstädt U, Schwarz NG, Hagen RM. Matrix-Dependent Sensitivity of Two Pan-Trematode PCR Assays for Detecting Schistosoma spp. in Clinical Human Samples. Infectious Disease Reports. 2026;18(2):27. doi:10.3390/idr18020027

BibTeX
@article{Frickmann2026,
  author = {Frickmann, Hagen and Hahn, Andreas and Eberhardt, Kirsten Alexandra and Loderstädt, Ulrike and Schwarz, Norbert Georg and Hagen, Ralf Matthias},
  title = {Matrix-Dependent Sensitivity of Two Pan-Trematode PCR Assays for Detecting Schistosoma spp. in Clinical Human Samples},
  journal = {Infectious Disease Reports},
  year = {2026},
  volume = {18},
  number = {2},
  pages = {27},
  doi = {10.3390/idr18020027}
}
Kostenlos starten →