EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Beyond One-Dimension: How Transient Groundwater Flow Amplifies Groundwater Evapotranspiration and Extinction Depth

Jia-Xin Shi, Linpeng Chen, Zhi-Yuan Zhang, Peng-Fei Han, Hongjuan Dong, Zhenbin Zhang

Hydrology · 16.03.2026 · 13 (3) · 97

DOI: 10.3390/hydrology13030097 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Hydrology, online erschienen am 16.03.2026. Verfasst von Jia-Xin Shi und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Liaoning Province, Key Laboratory of Groundwater Conservation of Ministry of Water Resources Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate quantification of groundwater evapotranspiration (ETg) is essential for reliable water resource assessment. Existing methods for estimating ETg from water table fluctuation largely rely on one-dimensional simplifications that neglect transient groundwater flow. However, in areas with shallow water table and topographic relief, where transient groundwater flow often occurs, the validity and accuracy of this simplification remain inadequately evaluated. In this study, we used HYDRUS-2D to construct a 50 m-long sandy hillslope with a 0.05 gradient to investigate ETg based on the water table fluctuation (WTF) method under transient groundwater flow conditions. The results indicate that periodic evapotranspiration generates water table fluctuations along the hillslope that exhibit amplitude attenuation and temporal phase lag, features not captured by 1D models. Ignoring transient groundwater flow leads to a systematic underestimation of ETg by up to 85% in sandy soil near the topographic lows. Furthermore, we found that both the decoupling depth and the extinction depth are significantly amplified by lateral groundwater flow, by up to 66% and 51%, respectively, compared with 1D estimates derived from the Shah method. These findings highlight the importance of incorporating transient flow processes into ETg estimation to improve the accuracy of water balance assessments and ecohydrological predictions, particularly in areas with shallow water tables and topographic relief.

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Liaoning Province
  • Key Laboratory of Groundwater Conservation of Ministry of Water Resources Foundation

Zitieren

APA

Shi, J., Chen, L., Zhang, Z., Han, P., Dong, H., & Zhang, Z. (2026). Beyond One-Dimension: How Transient Groundwater Flow Amplifies Groundwater Evapotranspiration and Extinction Depth. Hydrology, 13(3), 97. https://doi.org/10.3390/hydrology13030097

Vancouver

Shi J, Chen L, Zhang Z, Han P, Dong H, Zhang Z. Beyond One-Dimension: How Transient Groundwater Flow Amplifies Groundwater Evapotranspiration and Extinction Depth. Hydrology. 2026;13(3):97. doi:10.3390/hydrology13030097

BibTeX
@article{Shi2026,
  author = {Shi, Jia-Xin and Chen, Linpeng and Zhang, Zhi-Yuan and Han, Peng-Fei and Dong, Hongjuan and Zhang, Zhenbin},
  title = {Beyond One-Dimension: How Transient Groundwater Flow Amplifies Groundwater Evapotranspiration and Extinction Depth},
  journal = {Hydrology},
  year = {2026},
  volume = {13},
  number = {3},
  pages = {97},
  doi = {10.3390/hydrology13030097}
}
Kostenlos starten →