Operating Characteristics of Diaphragm Compressors in Hydrogen Refueling Stations Based on Actual Operational Data
Hydrogen · 16.10.2026 · 7 (4) · 157
DOI: 10.3390/hydrogen7040157 ↗Kurz gefasst
Fachartikel in der Zeitschrift Hydrogen, online erschienen am 16.10.2026. Verfasst von Yanming Wan und 5 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key R&D Program of China.
Abstract (Originalsprache)
With the rapid development of the hydrogen energy industry, hydrogen refueling stations have become a critical component of hydrogen infrastructure, and the operational performance of their core compression equipment directly affects the safety and reliability of the entire station. Due to its excellent sealing performance, the diaphragm compressor has become the preferred compression equipment for hydrogen refueling stations. In this study, a diaphragm compressor installed in a high-load commercial hydrogen refueling station was selected as the research subject. Long-term operational data of key thermodynamic parameters, including pressure, temperature, and mass flow rate, were collected to investigate the variations in the compressor’s macroscopic performance under various typical operating conditions and to identify the associated influencing factors. The results reveal the intrinsic relationships among parameter fluctuations, load variations, and equipment operating states during compressor operation. This study provides data support for the design methodology, operational strategies, and health management of diaphragm compressors in hydrogen refueling stations. It also offers new insights and references for improving the reliability of critical equipment in hydrogen refueling stations.
Förderung
- National Key R&D Program of China
Zitieren
APA
Wan, Y., Wan, S., Tian, Z., Ren, S., Jia, X., & Peng, X. (2026). Operating Characteristics of Diaphragm Compressors in Hydrogen Refueling Stations Based on Actual Operational Data. Hydrogen, 7(4), 157. https://doi.org/10.3390/hydrogen7040157
Vancouver
Wan Y, Wan S, Tian Z, Ren S, Jia X, Peng X. Operating Characteristics of Diaphragm Compressors in Hydrogen Refueling Stations Based on Actual Operational Data. Hydrogen. 2026;7(4):157. doi:10.3390/hydrogen7040157
BibTeX
@article{Wan2026,
author = {Wan, Yanming and Wan, Shixin and Tian, Zhonghui and Ren, Shengdong and Jia, Xiaohan and Peng, Xueyuan},
title = {Operating Characteristics of Diaphragm Compressors in Hydrogen Refueling Stations Based on Actual Operational Data},
journal = {Hydrogen},
year = {2026},
volume = {7},
number = {4},
pages = {157},
doi = {10.3390/hydrogen7040157}
}
EUVIMED