EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

Flow Cytometry Immunophenotyping in Hematology Clinical Practice: Panacea or a Diagnostic Tool? Conclusions from a Case Report

Georgios Boutsikas, Konstantinos Agiannitopoulos, Ioannis Anagnostopoulos, Myrofora Vikentiou, Maria Roumelioti, Athanasios Papatheodorou, Elisavet Kouvidi, Andriana Panoutsou, Georgios Georgiou, Aglaia Dimitrakopoulou, Nikolaos Paschalidis, Elisavet Economaki und 1 weitere

Hemato · 22.06.2026 · 7 (2) · 22

DOI: 10.3390/hemato7020022 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Hemato, online erschienen am 22.06.2026. Verfasst von Georgios Boutsikas und 12 weiteren Autor:innen. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Flow cytometry is an essential diagnostic method in hematology, and one of its main applications is the assessment of the clonality of mature B cells. We present a case report of a patient referred for the investigation of absolute lymphocytosis. The flow cytometry study revealed an increased percentage of B cells, but it could not establish B-cell clonality, based on the study of surface light chains in combination with the pattern of expression of mature B-cell markers. The diagnosis of Persistent Polyclonal B-cell Lymphocytosis (PPBL) was considered in the differential diagnosis as the mature B cells were found to be immunophenotypically memory B cells. However, due to the markedly elevated count of B cells, molecular testing with Polymerase Chain Reaction (PCR) for B-cell clonality based on IGH (Immunoglobulin Heavy Chain) gene rearrangements was performed, and it revealed the presence of two clones of B cells. Approximately one year later, the same work-up was repeated in the patient’s bone marrow aspirate. By flow cytometry, a distinct clonal B-cell population was isolated, while the molecular testing with PCR for B cell clonality based on IGH heavy-chain gene rearrangements revealed the presence of three clones of B cells. In addition, evaluation of the sample with high-dimensional mass cytometry showed the presence of four major immunophenotypically abnormal B-cell subsets.

Zitieren

APA

Boutsikas, G., Agiannitopoulos, K., Anagnostopoulos, I., Vikentiou, M., Roumelioti, M., Papatheodorou, A., Kouvidi, E., Panoutsou, A., Georgiou, G., Dimitrakopoulou, A., Paschalidis, N., Economaki, E., & Pouliou, E. (2026). Flow Cytometry Immunophenotyping in Hematology Clinical Practice: Panacea or a Diagnostic Tool? Conclusions from a Case Report. Hemato, 7(2), 22. https://doi.org/10.3390/hemato7020022

Vancouver

Boutsikas G, Agiannitopoulos K, Anagnostopoulos I, Vikentiou M, Roumelioti M, Papatheodorou A, et al. Flow Cytometry Immunophenotyping in Hematology Clinical Practice: Panacea or a Diagnostic Tool? Conclusions from a Case Report. Hemato. 2026;7(2):22. doi:10.3390/hemato7020022

BibTeX
@article{Boutsikas2026,
  author = {Boutsikas, Georgios and Agiannitopoulos, Konstantinos and Anagnostopoulos, Ioannis and Vikentiou, Myrofora and Roumelioti, Maria and Papatheodorou, Athanasios and Kouvidi, Elisavet and Panoutsou, Andriana and Georgiou, Georgios and Dimitrakopoulou, Aglaia and Paschalidis, Nikolaos and Economaki, Elisavet and Pouliou, Evdoxia},
  title = {Flow Cytometry Immunophenotyping in Hematology Clinical Practice: Panacea or a Diagnostic Tool? Conclusions from a Case Report},
  journal = {Hemato},
  year = {2026},
  volume = {7},
  number = {2},
  pages = {22},
  doi = {10.3390/hemato7020022}
}
Kostenlos starten →