Abstract (Originalsprache)
Background
Right anterior thoracotomy aortic valve replacement (RAT-AVR) is an established minimally invasive alternative to conventional sternotomy, but published experience largely reflects late-experience series from specialised centres. Data describing operative technique and early outcomes during real-world adoption remain limited.
Methods
We describe our operative technique and early outcomes in 156 consecutive intended isolated RAT-AVR procedures performed by a single surgeon between January 2015 and November 2025. Operative times were compared between the first 50 and subsequent 106 cases and assessed using cumulative sum analysis.
Results
Median age was 70 years and median EuroSCORE II was 1.00% [IQR 0.71–1.56]. Peripheral cannulation was used in most cases, with central cannulation employed selectively. Mechanical and biological prostheses spanning 19–29 mm were implanted, demonstrating that prosthesis choice was not restricted in this cohort. Median cardiopulmonary bypass and cross-clamp times were 109 and 79 min, respectively. Both were shorter after the first 50 cases (120.5 versus 106.0 min, p = 0.003; 85.5 versus 77.0 min, p = 0.048). Conversion to sternotomy occurred in two patients, both of whom survived to discharge and 30 days. Thirty-day mortality was 2/156 (1.3%).
Conclusions
This consecutive single-surgeon experience supports the feasibility and early safety of RAT-AVR in selected patients, with operative efficiency improving during adoption. RAT-AVR represents a pragmatic minimally invasive option for isolated surgical aortic valve replacement.
Zitieren
APA
Shell, D., Mekhail, A., Jaithong, P., & Yap, C. (2026). Right Anterior Thoracotomy Aortic Valve Replacement: Technique and Early Outcomes in 156 Patients. Hearts, 7(4), 34. https://doi.org/10.3390/hearts7040034
Vancouver
Shell D, Mekhail A, Jaithong P, Yap C. Right Anterior Thoracotomy Aortic Valve Replacement: Technique and Early Outcomes in 156 Patients. Hearts. 2026;7(4):34. doi:10.3390/hearts7040034
BibTeX
@article{Shell2026,
author = {Shell, Daniel and Mekhail, Andrew and Jaithong, Ploy and Yap, Cheng-Hon},
title = {Right Anterior Thoracotomy Aortic Valve Replacement: Technique and Early Outcomes in 156 Patients},
journal = {Hearts},
year = {2026},
volume = {7},
number = {4},
pages = {34},
doi = {10.3390/hearts7040034}
}
EUVIMED