EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

X-ray-Based 3D Histology of Murine Hearts Using Contrast-Enhanced Microfocus Computed Tomography (CECT) and Cryo-CECT

Camille Pestiaux, Alice Marino, Lauriane Simal, Sandrine Horman, Romain Capoulade, Greet Kerckhofs

Hearts · 23.12.2023 · 5 (1) · 14-28

DOI: 10.3390/hearts5010002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Hearts, online erschienen am 23.12.2023. Verfasst von Camille Pestiaux und 5 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Action de Recherche Concertée, ASBL Jean Degroof-Marcel Van Massenhove funding, UCLouvain Foundation Saint-Luc (RM2A project).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cardiovascular diseases are the most common cause of death worldwide, and they still have dramatic consequences on the patients’ lives. Murine models are often used to study the anatomical and microstructural changes caused by the diseases. Contrast-enhanced microfocus computed tomography (CECT) is a new imaging technique for 3D histology of biological tissues. In this study, we confirmed the nondestructiveness of Hf-WD 1:2 POM-based CECT and cryogenic CECT (cryo-CECT) to image the heart in 3D. The influence of the image quality (i.e., acquisition time and spatial resolution) was assessed for the characterization of the heart structural constituents: heart integrity, the coronary blood vessels and the heart valves. Coronary blood vessels were visualized and segmented in murine hearts, allowing us to distinguish veins from arteries and to visualize the 3D spatial distribution of the right coronary artery and the left main coronary artery. Finally, to demonstrate the added value of 3D imaging, the thickness distribution of the two leaflets in the mitral valve and three cusps in the aortic valve was computed in 3D. This study corroborates the added value of CECT and cryo-CECT compared to classical 2D histology to characterize ex vivo the structural properties of murine hearts and paves the way for the detailed 3D (micro)structural analyses of future cardiovascular disease models obtained in mice and rats.

Förderung

  • Action de Recherche Concertée
  • ASBL Jean Degroof-Marcel Van Massenhove funding
  • UCLouvain Foundation Saint-Luc (RM2A project)
  • Fonds National de la Recherche Scientifique (FNRS), Belgium
  • ARC
  • Région Pays de la Loire and Nantes Métropole. Avizo 2022.1
  • FNRS

Zitieren

APA

Pestiaux, C., Marino, A., Simal, L., Horman, S., Capoulade, R., & Kerckhofs, G. (2023). X-ray-Based 3D Histology of Murine Hearts Using Contrast-Enhanced Microfocus Computed Tomography (CECT) and Cryo-CECT. Hearts, 5(1), 14-28. https://doi.org/10.3390/hearts5010002

Vancouver

Pestiaux C, Marino A, Simal L, Horman S, Capoulade R, Kerckhofs G. X-ray-Based 3D Histology of Murine Hearts Using Contrast-Enhanced Microfocus Computed Tomography (CECT) and Cryo-CECT. Hearts. 2023;5(1):14-28. doi:10.3390/hearts5010002

BibTeX
@article{Pestiaux2023,
  author = {Pestiaux, Camille and Marino, Alice and Simal, Lauriane and Horman, Sandrine and Capoulade, Romain and Kerckhofs, Greet},
  title = {X-ray-Based 3D Histology of Murine Hearts Using Contrast-Enhanced Microfocus Computed Tomography (CECT) and Cryo-CECT},
  journal = {Hearts},
  year = {2023},
  volume = {5},
  number = {1},
  pages = {14--28},
  doi = {10.3390/hearts5010002}
}
Kostenlos starten →