An Assessment of the Performance Limitations of the Integrated QuantifilerTM Trio-HRM Assay: A Forensic Tool Designed to Identify Mixtures at the Quantification Stage
Genes · 2024
DOI: 10.3390/genes15060768 ↗Kurz gefasst
Fachartikel in der Zeitschrift Genes, 2024. Verfasst von Chastyn Smith und 3 weiteren Autor:innen. Beteiligte Einrichtung: Integrative Life Sciences, Virginia Commonwealth University, 1000 Cary Street, Richmond, VA 23284, USA. Hauptthemen laut MEDLINE: Forensic Genetics. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institute of Justice.
Abstract (Originalsprache)
Although guidelines exist for identifying mixtures, these measures often occur at the end-point of analysis and are protracted. To facilitate early mixture detection, we integrated a high-resolution melt (HRM) mixture screening assay into the qPCR step of the forensic workflow, producing the integrated QuantifilerTM Trio-HRM assay. The assay, when coupled with a prediction tool, allowed for 75.0% accurate identification of the contributor status of a sample (single source vs. mixture). To elucidate the limitations of the developed qPCR-HRM assay, developmental validation studies were conducted assessing the reproducibility and samples with varying DNA ratios, contributors, and quality. From this work, it was determined that the integrated QuantifilerTM Trio-HRM assay is capable of accurately identifying mixtures with up to five contributors and mixtures at ratios up to 1:100. Further, the optimal performance concentration range was found to be between 0.025 and 0.5 ng/µL. With these results, evidentiary-like DNA samples were then analyzed, resulting in 100.0% of the mixture samples being accurately identified; furthermore, every time a sample was predicted as a single source, it was true, giving confidence to any single-source calls. Overall, the integrated QuantifilerTM Trio-HRM assay has exhibited an enhanced ability to discern mixture samples from single-source samples at the qPCR stage under commonly observed conditions regardless of the contributor’s sex.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Integrative Life Sciences, Virginia Commonwealth University, 1000 Cary Street, Richmond, VA 23284, USA.
- Department of Forensic Science, Virginia Commonwealth University, 1015 Floyd Avenue, Richmond, VA 23284, USA.
- Department of Statistical Sciences & Operations Research, Virginia Commonwealth University, 1015 Floyd Avenue, Richmond, VA 23284, USA.
ORCID-Profile: Sarah J Seashols-Williams, Edward L Boone, Tracey Dawson Green
Förderung
- National Institute of Justice
Zitieren
APA
Smith, C., Seashols-Williams, S. J., Boone, E. L., & Dawson Green, T. (2024). An Assessment of the Performance Limitations of the Integrated QuantifilerTM Trio-HRM Assay: A Forensic Tool Designed to Identify Mixtures at the Quantification Stage. Genes. https://doi.org/10.3390/genes15060768
Vancouver
Smith C, Seashols-Williams SJ, Boone EL, Dawson Green T. An Assessment of the Performance Limitations of the Integrated QuantifilerTM Trio-HRM Assay: A Forensic Tool Designed to Identify Mixtures at the Quantification Stage. Genes. 2024. doi:10.3390/genes15060768
BibTeX
@article{Smith2024,
author = {Smith, Chastyn and Seashols-Williams, Sarah J and Boone, Edward L and Dawson Green, Tracey},
title = {An Assessment of the Performance Limitations of the Integrated QuantifilerTM Trio-HRM Assay: A Forensic Tool Designed to Identify Mixtures at the Quantification Stage},
journal = {Genes},
year = {2024},
doi = {10.3390/genes15060768}
}
EUVIMED