Evaluation of Liftover Tools for the Conversion of Genome Reference Consortium Human Build 37 to Build 38 Using ClinVar Variants
Genes · 26.09.2023 · 14 (10) · 1875
DOI: 10.3390/genes14101875 ↗Kurz gefasst
Fachartikel in der Zeitschrift Genes, online erschienen am 26.09.2023. Verfasst von Kyoung-Jin Park und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine & Genetics, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon 51353, Republic of Kore…. Hauptthemen laut MEDLINE: Genome, Human. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Soonchunhyang University Research Fund, National Research Foundation of Korea.
Abstract (Originalsprache)
Although Genome Reference Consortium Human Build 38 (GRCh38) was released with improvement over GRCh37, it has not been widely adopted. Several liftover tools have been developed as a convenient approach for GRCh38 implementation. This study aimed to investigate the accuracy of liftover tools for genome conversion. Two Variant Call Format (VCF) files aligned to GRCh37 and GRCh38 were downloaded from ClinVar (clinvar_20221217.vcf.gz). Liftover tools such as CrossMap, NCBI Remap, and UCSC liftOver were used to convert genome coordinates from GRCh37 to GRCh38. The accuracy of CrossMap, NCBI Remap, and UCSC liftOver were 99.81% (1,567,838/1,570,748), 99.69% (1,565,953/1,570,748), and 99.99% (1,570,550/1,570,748), respectively. Variants that failed conversion via all three liftover tools were all indels/duplications: a pathogenic/likely pathogenic variant (n = 1) and benign/likely benign variants (n = 7). The eight variants that failed conversion were identified in the ALMS, TTN, CFTR, SLCO, LDLR, PCNT, MID1, and GRIA3 genes, and all the variants were not in the VCF files aligned to GRCh37. This study demonstrated that three liftover tools could successfully convert reference genomes from GRCh37 to GRCh38 in more than 99% of ClinVar variants. This study takes the first step to clinically implement GRCh38 using liftover tools. Further clinical studies are warranted to compare the performance of liftover tools and to validate re-alignment approaches in routine clinical settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Laboratory Medicine & Genetics, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon 51353, Republic of Korea.
- Department of Laboratory Medicine, Soonchunhyang University Cheonan Hospital, Soonchunhyang University College of Medicine, Cheonan 31151, Republic of Korea.
- Clinical Genomics Center, Samsung Medical Center, Seoul 06351, Republic of Korea.
Förderung
- Soonchunhyang University Research Fund
- National Research Foundation of Korea
Zitieren
APA
Park, K. J., Yoon, Y. A., & Park, J. H. (2023). Evaluation of Liftover Tools for the Conversion of Genome Reference Consortium Human Build 37 to Build 38 Using ClinVar Variants. Genes, 14(10), 1875. https://doi.org/10.3390/genes14101875
Vancouver
Park KJ, Yoon YA, Park JH. Evaluation of Liftover Tools for the Conversion of Genome Reference Consortium Human Build 37 to Build 38 Using ClinVar Variants. Genes. 2023;14(10):1875. doi:10.3390/genes14101875
BibTeX
@article{Park2023,
author = {Park, Kyoung-Jin and Yoon, Young Ahn and Park, Jong-Ho},
title = {Evaluation of Liftover Tools for the Conversion of Genome Reference Consortium Human Build 37 to Build 38 Using ClinVar Variants},
journal = {Genes},
year = {2023},
volume = {14},
number = {10},
pages = {1875},
doi = {10.3390/genes14101875}
}