Slide-Ring Microneedle Hydrogels for Sweat Monitoring Evaluated via a Benchtop Sweat Simulator
Gels · 27.10.2026 · 12 (11) · 973
DOI: 10.3390/gels12110973 ↗Kurz gefasst
Fachartikel in der Zeitschrift Gels, online erschienen am 27.10.2026. Verfasst von Manuel Ros-Sirvent und 5 weiteren Autor:innen. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: WEAROPSENS, LUXBIOSENS, PROMETEO.
Abstract (Originalsprache)
Wearable sweat sensors are promising tools for non-invasive biomarker monitoring, but their development is hindered by the lack of standardized testing platforms and human sweat variability. Although hydrogels with high swelling capacity are attractive for sweat collection, poor post-swelling mechanical resistance often limits their application. To overcome this limitation, this study presents a mechanically robust, highly swellable hydrogel featuring surface microneedles (MN) that enhance sweat absorption kinetics through capillary fluid dispersion without microstructural collapse. The microneedle patch incorporates a PDMS-molded hydrophilic copolymer network with PEG-β-cyclodextrin-based pseudopolyrotaxanes as mobile crosslinking junctions to promote stress dissipation and structural integrity. Additionally, a benchtop sweat simulator was developed to deliver synthetic sweat with tunable, reproducible flow rates, compositions, and temporal profiles through a programmable interface. Using colorimetric pH monitoring as a proof-of-concept, the hydrogel demonstrated excellent performance across simulated biological variability, highlighting the vital role of material design in accelerating wearable biosensor translation.
Förderung
- WEAROPSENS
- LUXBIOSENS
- PROMETEO
- UPV
Zitieren
APA
Ros-Sirvent, M., Chillagana, P., Lucío, M. I., Maquieira, Á., Tortajada-Genaro, L. A., & Bañuls, M. (2026). Slide-Ring Microneedle Hydrogels for Sweat Monitoring Evaluated via a Benchtop Sweat Simulator. Gels, 12(11), 973. https://doi.org/10.3390/gels12110973
Vancouver
Ros-Sirvent M, Chillagana P, Lucío MI, Maquieira Á, Tortajada-Genaro LA, Bañuls M. Slide-Ring Microneedle Hydrogels for Sweat Monitoring Evaluated via a Benchtop Sweat Simulator. Gels. 2026;12(11):973. doi:10.3390/gels12110973
BibTeX
@article{RosSirvent2026,
author = {Ros-Sirvent, Manuel and Chillagana, Pamela and Lucío, María Isabel and Maquieira, Ángel and Tortajada-Genaro, Luis Antonio and Bañuls, María-José},
title = {Slide-Ring Microneedle Hydrogels for Sweat Monitoring Evaluated via a Benchtop Sweat Simulator},
journal = {Gels},
year = {2026},
volume = {12},
number = {11},
pages = {973},
doi = {10.3390/gels12110973}
}
EUVIMED