Preparation of High Elongation and Low Hysteresis Conductive Hydrogels Strain Sensor Using Flake-like PEDOT Particles as Conductive Fillers
Gels · 15.06.2026 · 12 (6) · 536
DOI: 10.3390/gels12060536 ↗Kurz gefasst
Fachartikel in der Zeitschrift Gels, online erschienen am 15.06.2026. Verfasst von Xiyuan Duan und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials Science and Engineering, Hubei University, 368 Youyi Avenue, Wuchang District, Wuhan 430062, China. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China, National Key R&D Program of China.
Abstract (Originalsprache)
Conductive hydrogel strain sensors using poly(3,4-ethylenedioxythiophene) (PEDOT) as fillers are rapidly advancing and are emerging as candidates for monitoring devices such as wearable electronic skin. However, due to limitations such as low elongation and high hysteresis, it is difficult to fully leverage its promising sensor properties in practical applications. In this study, we synthesized flake-like PEDOT particles (FP particles) and used Polyacrylamide (PAM) as the hydrogel matrix to fabricate a conductive hydrogel strain sensor. These particles were obtained by grinding PEDOT particles prepared via a template-free method. After swelling with ethylene glycol (EG) and assembly with polyvinyl alcohol (PVA), the FP particles become porous and contain many hydroxyl groups. This design enables the adsorption of acrylamide (AM) monomers within FP particles, facilitating the in situ polymerization of PAM onto the PEDOT/PVA chains, thereby yielding a dual-network structure with strong entanglements. This gives the sensor high elongation and very low hysteresis. In addition, it offers favorable sensor performance, including high sensitivity, high repeatability, and reliability. This strain sensor can be used in wearable electronic skin applications for facial monitoring and motion detection.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Materials Science and Engineering, Hubei University, 368 Youyi Avenue, Wuchang District, Wuhan 430062, China.
- School of Materials Science and Engineering, Wuhan University of Science and Technology, 947 Heping Avenue, Qingshan District, Wuhan 430081, China.
ORCID-Profile: Xiyuan Duan
Förderung
- National Key Research and Development Program of China
- National Key R&D Program of China
Zitieren
APA
Duan, X., Wang, S., Wang, D., Gong, Y., & Jiang, Z. (2026). Preparation of High Elongation and Low Hysteresis Conductive Hydrogels Strain Sensor Using Flake-like PEDOT Particles as Conductive Fillers. Gels, 12(6), 536. https://doi.org/10.3390/gels12060536
Vancouver
Duan X, Wang S, Wang D, Gong Y, Jiang Z. Preparation of High Elongation and Low Hysteresis Conductive Hydrogels Strain Sensor Using Flake-like PEDOT Particles as Conductive Fillers. Gels. 2026;12(6):536. doi:10.3390/gels12060536
BibTeX
@article{Duan2026,
author = {Duan, Xiyuan and Wang, Shimin and Wang, Daheng and Gong, Yu and Jiang, Ziwei},
title = {Preparation of High Elongation and Low Hysteresis Conductive Hydrogels Strain Sensor Using Flake-like PEDOT Particles as Conductive Fillers},
journal = {Gels},
year = {2026},
volume = {12},
number = {6},
pages = {536},
doi = {10.3390/gels12060536}
}
EUVIMED