EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A High-Strength, Anti-Swelling Sodium Alginate/Polyacrylamide Hydrogel Strain Sensor for Underwater Motion Monitoring and Information Transmission

Xuecui Song, Jing Guo, Wei Chen, Mengya Liu, Yihang Zhang, Wenhui Xiao, Fucheng Guan

Gels · 28.05.2026 · 12 (6) · 468

DOI: 10.3390/gels12060468 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Gels, online erschienen am 28.05.2026. Verfasst von Xuecui Song und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Textile and Material Engineering, Dalian Polytechnic University, Dalian 116034, China. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 67 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Educational Department of Liaoning Province, Liaoning Provincial Department of Education.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Recently, conductive hydrogels have gained extensive applications in flexible wearable electronics and have garnered considerable attention. However, their inherent swelling behaviour and limited mechanical strength have hindered their further development. In this study, a polyacrylamide/sodium alginate (PAM/SA, PS)-based hydrogel with high mechanical strength and anti-swelling properties was prepared by combining mechanical stretching–drying pretreatment with a bimetallic ion (Li+/multivalent metal ion) post-soaking strategy. Among multivalent metal ions (Ca2+, Al3+, and Zr4+), the Al3+-crosslinked hydrogel (PS-Al3+) demonstrated outstanding overall performance. It exhibited excellent mechanical properties, with tensile strength, elongation at break, and impact strength reaching 9.71 MPa, 993.53%, and 75 MJ/m3, respectively. Its dense network structure also gave it excellent anti-swelling properties (swelling ratio of 14%). As a strain sensor, the PS-Al3+ hydrogel displayed good conductivity (1.33 S/m), high sensitivity (GF = 2.25), fast response (response time of 403 ms), and negligible hysteresis (recovery time of 407 ms). Benefiting from its exceptional resistance to expansion, the material’s sensor response signals in underwater environments are highly consistent with those in air. Furthermore, this sensor has been successfully applied to swimming motion monitoring and data transmission in underwater environments. This study proposes a novel, low-cost, and simple approach for developing flexible sensors suitable for underwater environments.

Schlagwörter

Stichwörter der Autor:innen

anti-swellingionic conductive hydrogelunderwater communicationwearable strain sensor

Autor:innen und Institutionen

  • School of Textile and Material Engineering, Dalian Polytechnic University, Dalian 116034, China.

Förderung

  • Educational Department of Liaoning Province
  • Liaoning Provincial Department of Education

Zitieren

APA

Song, X., Guo, J., Chen, W., Liu, M., Zhang, Y., Xiao, W., & Guan, F. (2026). A High-Strength, Anti-Swelling Sodium Alginate/Polyacrylamide Hydrogel Strain Sensor for Underwater Motion Monitoring and Information Transmission. Gels, 12(6), 468. https://doi.org/10.3390/gels12060468

Vancouver

Song X, Guo J, Chen W, Liu M, Zhang Y, Xiao W, et al. A High-Strength, Anti-Swelling Sodium Alginate/Polyacrylamide Hydrogel Strain Sensor for Underwater Motion Monitoring and Information Transmission. Gels. 2026;12(6):468. doi:10.3390/gels12060468

BibTeX
@article{Song2026,
  author = {Song, Xuecui and Guo, Jing and Chen, Wei and Liu, Mengya and Zhang, Yihang and Xiao, Wenhui and Guan, Fucheng},
  title = {A High-Strength, Anti-Swelling Sodium Alginate/Polyacrylamide Hydrogel Strain Sensor for Underwater Motion Monitoring and Information Transmission},
  journal = {Gels},
  year = {2026},
  volume = {12},
  number = {6},
  pages = {468},
  doi = {10.3390/gels12060468}
}
Kostenlos starten →