EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Introducing CdZnTe Detectors into Measuring 222Rn Concentrations in Water

Ioannis Kaissas, Konstantinos Karafasoulis, Aris Kyriakis, Panagiotis Papaprokopiou

Gases · 03.06.2026 · 6 (2) · 29

DOI: 10.3390/gases6020029 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Gases, online erschienen am 03.06.2026. Verfasst von Ioannis Kaissas und 3 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Radon (222Rn) is a noble, radioactive gas and tends to be accumulated in poorly ventilated enclosed spaces. Mainly due to its radioactive daughters and the α-particles emitted, 222Rn poses a risk of cancer and therefore its concentration in air and water should be kept under certain reference levels. Several methods have been developed to accurately measure 222Rn concentration in water, using α, β or γ counting. A well-established, but not the only, method involves γ-spectroscopy using a High-Purity Germanium (HPGe) detector to identify the 222Rn decay isotopes 214Pb and 214Bi, assuming they are in secular equilibrium with 222Rn. This technique requires costly, bulky equipment due to the HPGe’s operation at −196 °C and the need for substantial shielding. The present study introduces a more affordable and compact device, utilizing CdZnTe (CZT) crystals, which provide exceptional energy resolution in the 300 to 600 keV range, with nearly eight times the Full Width at Half Maximum (FWHM) of HPGe. Four stacked CZT detectors, each containing a 0.5 cm3 crystal, were compared with measurements from an HPGe detector. Water samples were collected from boreholes and taps in a region where radon concentration in water ranged from 10 to 900 Bq/L. The results are promising for samples around 100 Bq/L, considering the potential advancements of the device with larger CZT detectors. Additionally, the method has the potential for in situ use due to its handheld capability.

Zitieren

APA

Kaissas, I., Karafasoulis, K., Kyriakis, A., & Papaprokopiou, P. (2026). Introducing CdZnTe Detectors into Measuring 222Rn Concentrations in Water. Gases, 6(2), 29. https://doi.org/10.3390/gases6020029

Vancouver

Kaissas I, Karafasoulis K, Kyriakis A, Papaprokopiou P. Introducing CdZnTe Detectors into Measuring 222Rn Concentrations in Water. Gases. 2026;6(2):29. doi:10.3390/gases6020029

BibTeX
@article{Kaissas2026,
  author = {Kaissas, Ioannis and Karafasoulis, Konstantinos and Kyriakis, Aris and Papaprokopiou, Panagiotis},
  title = {Introducing CdZnTe Detectors into Measuring 222Rn Concentrations in Water},
  journal = {Gases},
  year = {2026},
  volume = {6},
  number = {2},
  pages = {29},
  doi = {10.3390/gases6020029}
}
Kostenlos starten →