Hydrogen Sulfide Removal from Flare Gas
Gases · 07.05.2026 · 6 (2) · 22
DOI: 10.3390/gases6020022 ↗Kurz gefasst
Fachartikel in der Zeitschrift Gases, online erschienen am 07.05.2026. Verfasst von Yousef Alqaheem. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Kuwait Institute for Scientific Research.
Abstract (Originalsprache)
Flaring is necessary to prevent pressure buildup in the unit. Due to hydrotreatment processes at the refinery, flare gas can contain significant amounts of hydrogen sulfide. Combusting this gas can result in environmental and health issues. One method to reduce hydrogen sulfide is to replace the water in the seal drum with an amine solution. Honeywell UniSIM® process simulation was used to calculate the hydrogen sulfide removal efficiency with 45 wt% MDEA solution. Results show that removal efficiency depends on amine loading and pool height. Removal efficiency of up to 72.5% was achieved with a hydrogen sulfide-to-amine molar loading of 0.2 (4:20 ratio) and a pool effective height of 2.5 m.
Förderung
- Kuwait Institute for Scientific Research
Zitieren
APA
Alqaheem, Y. (2026). Hydrogen Sulfide Removal from Flare Gas. Gases, 6(2), 22. https://doi.org/10.3390/gases6020022
Vancouver
Alqaheem Y. Hydrogen Sulfide Removal from Flare Gas. Gases. 2026;6(2):22. doi:10.3390/gases6020022