EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Application of a Multi-Gas Detector for Monitoring Gas Composition in Minced Beef During Storage

Aleksandar Veličković iD, Lorenzo Cocola iD, Massimo Fedel iD, Bojana Danilović iD, Massimo De Marchi iD, Luca Poletto, Dragiša Savić iD

Foods · 07.11.2024 · 13 (22) · 3553

DOI: 10.3390/foods13223553 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Foods, online erschienen am 07.11.2024. Verfasst von Aleksandar Veličković und 6 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Technology, University of Niš, Bulevar Oslobodjenja 124, 16000 Leskovac, Serbia. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aims to assess the capability of using a specially designed device to monitor changes in gas concentration (CO2, NH3, H2S, and O2) in the atmosphere above the minced beef meat, during storage at refrigerated temperature. With its array of sensing channels, the multi-gas detector device facilitates the detection of precise gas concentrations in sensitive environments, enabling the monitoring of various processes occurring within stored meat. To delve into the connection between microbial activity and gas emissions during storage, fluctuations in microbial populations in the meat were observed, focusing on prevalent meat microbiota such as lactic acid bacteria (LAB) and Enterobacteriaceae. A significant reduction of O2 content in the stored samples was observed after seven days (p < 0.05), while a significant release of CO2 was detected on the fourth day of storage. Significant changes (p < 0.05) in the gas content were tracked until the 11th day of storage followed by intensive microbial growth. NH3 and H2S levels remained undetectable throughout the experiment. The results showed a correlation between an increase in gas content in the headspace and an increase in the number of LAB and Enterobacteriaceae in meat. Modern multi-gas detector devices can indirectly determine microbial contamination in closed meat packaging.

Schlagwörter

Stichwörter der Autor:innen

ammoniabeef meathydrogen sulphidemicrobial countmulti-gas detector device

Autor:innen und Institutionen

  • Faculty of Technology, University of Niš, Bulevar Oslobodjenja 124, 16000 Leskovac, Serbia.
  • Department of Agricultural and Food Studies, Toplica Academy of Applied Studies, Ćirila i Metodija 1, 18400 Prokuplje, Serbia.
  • CNR Institute for Photonics and Nanotechnologies UOS Padova, Via Trasea 7, 35131 Padova, Italy.
  • Department of Agronomy, Food, Natural Resources, Animals and Environment (DAFNAE), University of Padova, Viale dell'Università 16, 35020 Legnaro, Italy.

ORCID-Profile: Aleksandar Veličković, Lorenzo Cocola, Massimo Fedel, Bojana Danilović, Massimo De Marchi, Dragiša Savić

Zitieren

APA

Veličković, A., Cocola, L., Fedel, M., Danilović, B., De Marchi, M., Poletto, L., & Savić, D. (2024). Application of a Multi-Gas Detector for Monitoring Gas Composition in Minced Beef During Storage. Foods, 13(22), 3553. https://doi.org/10.3390/foods13223553

Vancouver

Veličković A, Cocola L, Fedel M, Danilović B, De Marchi M, Poletto L, et al. Application of a Multi-Gas Detector for Monitoring Gas Composition in Minced Beef During Storage. Foods. 2024;13(22):3553. doi:10.3390/foods13223553

BibTeX
@article{Velikovi2024,
  author = {Veličković, Aleksandar and Cocola, Lorenzo and Fedel, Massimo and Danilović, Bojana and De Marchi, Massimo and Poletto, Luca and Savić, Dragiša},
  title = {Application of a Multi-Gas Detector for Monitoring Gas Composition in Minced Beef During Storage},
  journal = {Foods},
  year = {2024},
  volume = {13},
  number = {22},
  pages = {3553},
  doi = {10.3390/foods13223553}
}
Kostenlos starten →