Hydraulic Characterization of a Direct-Acting Pressure-Reducing Valve Using CFD and Experimental Validation

Gonzalo López-Villacís, Pablo Valle-Velasco, Martha Sevilla-Abarca, Diana Peralta-Zurita, Segundo Espín-Lagos

Fluids · 02.06.2026 · 11 (6) · 139

DOI: 10.3390/fluids11060139 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Fluids, online erschienen am 02.06.2026. Verfasst von Gonzalo López-Villacís und 4 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universidad Técnica de Ambato.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents the hydraulic characterization of a direct-acting pressure-reducing valve (PRV) using a combined experimental and numerical approach. An experimental test bench was implemented to measure inlet, control port, and outlet pressures over a flow rate range from 0 to 4.0 m3/h, under a constant inlet pressure of 8 bar and a set pressure of 3 bar. In parallel, a three-dimensional steady-state CFD model was developed using a sequential force balance analysis between hydraulic and spring restoring forces. The results show good agreement between numerical predictions and experimental data, with a maximum error below 10% in outlet pressure. The pressure drop exhibited a nonlinear increasing trend with flow rate, reaching values close to 1.8 bar at 4.0 m3/h. The flow coefficient Kv remained within a range of 2.2–3.0, while the pressure regulation coefficient S remained below 0.05, indicating stable regulation performance. Additional simulations at 25 bar provided improved agreement with manufacturer data, suggesting that catalog curves may be based on nominal pressure conditions. The proposed methodology demonstrates that steady-state CFD coupled with force balance analysis is an effective and computationally efficient approach for predicting the hydraulic behavior of direct-acting PRVs.

Förderung

  • Universidad Técnica de Ambato

Zitieren

APA

López-Villacís, G., Valle-Velasco, P., Sevilla-Abarca, M., Peralta-Zurita, D., & Espín-Lagos, S. (2026). Hydraulic Characterization of a Direct-Acting Pressure-Reducing Valve Using CFD and Experimental Validation. Fluids, 11(6), 139. https://doi.org/10.3390/fluids11060139

Vancouver

López-Villacís G, Valle-Velasco P, Sevilla-Abarca M, Peralta-Zurita D, Espín-Lagos S. Hydraulic Characterization of a Direct-Acting Pressure-Reducing Valve Using CFD and Experimental Validation. Fluids. 2026;11(6):139. doi:10.3390/fluids11060139

BibTeX
@article{LpezVillacs2026,
  author = {López-Villacís, Gonzalo and Valle-Velasco, Pablo and Sevilla-Abarca, Martha and Peralta-Zurita, Diana and Espín-Lagos, Segundo},
  title = {Hydraulic Characterization of a Direct-Acting Pressure-Reducing Valve Using CFD and Experimental Validation},
  journal = {Fluids},
  year = {2026},
  volume = {11},
  number = {6},
  pages = {139},
  doi = {10.3390/fluids11060139}
}
Kostenlos starten →