EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Prediction of Cable Thermal Failure in Switchgear Rooms of Nuclear Power Plants Based on Numerical Simulation and Deep Learning

Xu Zhai, Jiling Wu, Hongru Zhao, Jun Zhao, Xinhui Fu, Jinlong Zhao

Fire · 18.11.2026 · 9 (11) · 523

DOI: 10.3390/fire9110523 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Fire, online erschienen am 18.11.2026. Verfasst von Xu Zhai und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Thermal failure of critical cables in nuclear power plants may result in the loss of safety functions, thereby compromising the safe and stable operation of the plant. This study focuses on the switchgear room of a nuclear power plant and investigates cable thermal failure under FDS-simulated fire scenarios with varying HRR, while the ignition location, ventilation, compartment openings, and cable arrangement are fixed, employing numerical simulation and deep learning approaches. First, numerical simulations of switchgear cabinet fires were conducted using the Fire Dynamics Simulator (FDS) for 15 different heat release rates (HRR). Second, to address the limitation that existing models mainly predict static outcomes, three deep learning models were trained to capture the continuous dynamic temperature evolution on datasets derived from the simulation results, and their predictive performance was evaluated using the R2, RMSE, and MAE. Third, taking 330 °C as the thermal failure threshold for cables, the thermal failure behavior under representative HRR conditions was predicted. The results indicate that the MLP model achieves the best prediction accuracy, with R2, RMSE, and MAE values of 0.96, 11.63, and 5.77, respectively, whereas the Transformer model exhibits the poorest performance, with corresponding values of 0.90, 28.23, and 9.92. Using the optimal MLP model, the thermal failure behavior of cables under typical conditions was further analyzed. The predictions reveal that the critical HRR of the switchgear cabinet at which the critical cables reach thermal failure is 550 kW, and the time to failure exhibits a nonlinear decay with increasing HRR. Specifically, at HRR levels of 702 kW and 1002 kW, the predicted failure times are 709 s and 594 s, respectively. These findings demonstrate that deep learning models can efficiently and accurately predict temperature evolution under FDS-simulated fire scenarios in a nuclear power plant switchgear room, thereby providing methodological support for fire protection design and emergency decision making.

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China

Zitieren

APA

Zhai, X., Wu, J., Zhao, H., Zhao, J., Fu, X., & Zhao, J. (2026). Prediction of Cable Thermal Failure in Switchgear Rooms of Nuclear Power Plants Based on Numerical Simulation and Deep Learning. Fire, 9(11), 523. https://doi.org/10.3390/fire9110523

Vancouver

Zhai X, Wu J, Zhao H, Zhao J, Fu X, Zhao J. Prediction of Cable Thermal Failure in Switchgear Rooms of Nuclear Power Plants Based on Numerical Simulation and Deep Learning. Fire. 2026;9(11):523. doi:10.3390/fire9110523

BibTeX
@article{Zhai2026,
  author = {Zhai, Xu and Wu, Jiling and Zhao, Hongru and Zhao, Jun and Fu, Xinhui and Zhao, Jinlong},
  title = {Prediction of Cable Thermal Failure in Switchgear Rooms of Nuclear Power Plants Based on Numerical Simulation and Deep Learning},
  journal = {Fire},
  year = {2026},
  volume = {9},
  number = {11},
  pages = {523},
  doi = {10.3390/fire9110523}
}