Fire Safety Assessment of Insulation Boards Made from Recycled Cotton Fibers: Part I—Thermal Properties and Fire Behavior
Fire · 11.09.2026 · 9 (9) · 394
DOI: 10.3390/fire9090394 ↗Kurz gefasst
Fachartikel in der Zeitschrift Fire, online erschienen am 11.09.2026. Verfasst von Tadeáš Zachara und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Czech University of Life Sciences Prague.
Abstract (Originalsprache)
Recycled cotton fibers offer a promising route for sustainable thermal insulation, but their flammability limits wider application. This study evaluated rigid recycled cotton insulation boards bonded with a polyvinyl acetate (PVAc)–starch system and modified with kraft lignin or aluminium trihydroxide (ATH) at dosages of 10 and 15 wt.%. Board density, thermal conductivity, volumetric heat capacity, thermal diffusivity, cone-calorimeter behavior, and ignitability under single-flame exposure were assessed. Thermal conductivity remained within a narrow range of 0.071–0.075 W·m−1·K−1, indicating that the basic insulation function was preserved despite formulation changes. Greater differences were observed in volumetric heat capacity and thermal diffusivity, particularly in lignin-modified boards at higher PVAc contents. Fire behavior was strongly formulation-dependent and showed no uniform dose-dependent response. The lowest peak heat release rate (pHRR) was obtained for the formulation containing 10 wt.% ATH and 20 wt.% PVAc, while the lowest total heat release (THR) was obtained for the formulation containing 10 wt.% ATH and 18 wt.% PVAc, reaching 170.31 kW·m−2 and 62.30 MJ·m−2, respectively. Lignin produced a less consistent effect on heat release. Under single-flame exposure, edge application was generally more critical than surface application, while ATH, particularly at 15 wt.%, provided the most consistent reduction in ignition and early flame spread. Overall, ATH was the more promising fire-modifying additive, although further formulation optimization and formal reaction-to-fire classification are required.
Förderung
- Czech University of Life Sciences Prague
Zitieren
APA
Zachara, T., Borůvka, V., Kytka, T., Petržela, B., Kubista, K., & Šedivka, P. (2026). Fire Safety Assessment of Insulation Boards Made from Recycled Cotton Fibers: Part I—Thermal Properties and Fire Behavior. Fire, 9(9), 394. https://doi.org/10.3390/fire9090394
Vancouver
Zachara T, Borůvka V, Kytka T, Petržela B, Kubista K, Šedivka P. Fire Safety Assessment of Insulation Boards Made from Recycled Cotton Fibers: Part I—Thermal Properties and Fire Behavior. Fire. 2026;9(9):394. doi:10.3390/fire9090394
BibTeX
@article{Zachara2026,
author = {Zachara, Tadeáš and Borůvka, Vlastimil and Kytka, Tomáš and Petržela, Benjamín and Kubista, Kryštof and Šedivka, Přemysl},
title = {Fire Safety Assessment of Insulation Boards Made from Recycled Cotton Fibers: Part I—Thermal Properties and Fire Behavior},
journal = {Fire},
year = {2026},
volume = {9},
number = {9},
pages = {394},
doi = {10.3390/fire9090394}
}