EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High-Silica Fiber/Silica Aerogel Composite for Bridge-Cable Fire Protection: HC-Fire Tests and Numerical Simulation

Senlin Yao, Shian Jin, Shaokun Ge, Ya Ni, Gaoming Du, Yingjian Hu, Yin Liang

Fire · 04.08.2026 · 9 (8) · 332

DOI: 10.3390/fire9080332 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Fire, online erschienen am 04.08.2026. Verfasst von Senlin Yao und 6 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: China Postdoctoral Science Foundation, China Academy of Safety Science and Technology, Beijing Natural Science Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluates high-silica fiber/silica aerogel composites (HSFACs) for the passive fire protection of bridge cables. The primary objective is to reveal the high-temperature degradation mechanism of HSFAC and quantitatively determine a reliable thickness scheme for long-term hydrocarbon-fire protection of bridge cables. HSFAC specimens were heat-treated and characterized by thermal conductivity, tensile testing, SEM/TEM, FTIR, and TG analysis. A self-built furnace was used to assess an HSFAC-based cable protection system under hydrocarbon-fire exposure. Increasing heat-treatment temperature enlarged the pore and particle sizes of HSFAC and reduced its thermal-insulation performance. During 120 min of fire exposure, the cable protected by a single 5 mm HSFAC layer reached 300 °C within 45 min, whereas the cable protected by a double-layer 5 + 5 mm HSFAC system remained below 300 °C throughout the test. Finite element simulations validated against the experimental results confirmed that increasing HSFAC thickness improved thermal protection. After 90 min, the predicted cable-surface temperatures were 556 °C and 314 °C for HSFAC thicknesses of 5 mm and 10 mm, respectively. By integrating high-temperature material characterization, HC-fire testing, and thickness-dependent numerical analysis, this study links material degradation to system-level fire performance and provides a quantitative basis for HSFAC thickness design.

Förderung

  • China Postdoctoral Science Foundation
  • China Academy of Safety Science and Technology
  • Beijing Natural Science Foundation

Zitieren

APA

Yao, S., Jin, S., Ge, S., Ni, Y., Du, G., Hu, Y., & Liang, Y. (2026). High-Silica Fiber/Silica Aerogel Composite for Bridge-Cable Fire Protection: HC-Fire Tests and Numerical Simulation. Fire, 9(8), 332. https://doi.org/10.3390/fire9080332

Vancouver

Yao S, Jin S, Ge S, Ni Y, Du G, Hu Y, et al. High-Silica Fiber/Silica Aerogel Composite for Bridge-Cable Fire Protection: HC-Fire Tests and Numerical Simulation. Fire. 2026;9(8):332. doi:10.3390/fire9080332

BibTeX
@article{Yao2026,
  author = {Yao, Senlin and Jin, Shian and Ge, Shaokun and Ni, Ya and Du, Gaoming and Hu, Yingjian and Liang, Yin},
  title = {High-Silica Fiber/Silica Aerogel Composite for Bridge-Cable Fire Protection: HC-Fire Tests and Numerical Simulation},
  journal = {Fire},
  year = {2026},
  volume = {9},
  number = {8},
  pages = {332},
  doi = {10.3390/fire9080332}
}