Thermal Damage Evolution and Structural Response of Transmission Tower Legs Under Localized Wood-Crib Fire Exposure
Fire · 14.06.2026 · 9 (6) · 254
DOI: 10.3390/fire9060254 ↗Kurz gefasst
Fachartikel in der Zeitschrift Fire, online erschienen am 14.06.2026. Verfasst von Haiwen Xu und 4 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: technology project of China Southern Power Grid Co., Ltd..
Abstract (Originalsprache)
Wildfires can threaten the safety of transmission towers by degrading galvanized coatings and reducing the load-bearing capacity of steel members exposed to elevated temperatures. This study investigates the thermal damage evolution and structural response of transmission tower legs under localized wood-crib fire exposure through a combined experimental and numerical approach. A 1:4 scale tower-leg model was subjected to a single wood-crib fire exposure for approximately 20 min, during which temperature histories, surface damage patterns, and deformation of the fire-exposed members were recorded. The results show that the maximum measured temperature reached 803 °C and decreased approximately linearly with height, leading to distinct damage zones along the tower leg. The galvanized coating exhibited progressive degradation, including oxidation, melting, cracking, and local peeling, while the surface appearance changed from bright silver to black and finally to gray-white with reddish-brown areas in severely heated regions. A temperature-informed elastic–plastic finite element model was then used to interpret the global structural response. The analysis indicates that elevated temperature reduced the stiffness and load-bearing capacity of the fire-exposed side, causing deformation concentration and torsional distortion in diagonal members. The proposed framework provides a practical basis for post-fire damage identification and rapid structural assessment of transmission towers in wildfire-prone regions.
Förderung
- technology project of China Southern Power Grid Co., Ltd.
Zitieren
APA
Xu, H., Huang, D., Li, P., Quan, X., & Peng, T. (2026). Thermal Damage Evolution and Structural Response of Transmission Tower Legs Under Localized Wood-Crib Fire Exposure. Fire, 9(6), 254. https://doi.org/10.3390/fire9060254
Vancouver
Xu H, Huang D, Li P, Quan X, Peng T. Thermal Damage Evolution and Structural Response of Transmission Tower Legs Under Localized Wood-Crib Fire Exposure. Fire. 2026;9(6):254. doi:10.3390/fire9060254
BibTeX
@article{Xu2026,
author = {Xu, Haiwen and Huang, Daochun and Li, Peng and Quan, Xincheng and Peng, Tianhao},
title = {Thermal Damage Evolution and Structural Response of Transmission Tower Legs Under Localized Wood-Crib Fire Exposure},
journal = {Fire},
year = {2026},
volume = {9},
number = {6},
pages = {254},
doi = {10.3390/fire9060254}
}
EUVIMED